Skip to content
Omnikalc

Two-way slab direct design method calculator

Enter the factored load, the spans and the column size to get the total static moment M0 of a two-way slab and its distribution to the negative and positive moments of the interior and end spans.

Updated on
Your inputs
psf

Value out of range

ft

Value out of range

ft

Value out of range

in

Value out of range

Results

Total static moment M0

311.7 kip-ft

Clear span ln
22.33 ft
Interior span, negative moment
202.6 kip-ft
Interior span, positive moment
109.1 kip-ft
End span, exterior negative moment
81.1 kip-ft
End span, positive moment
162.1 kip-ft
End span, interior negative moment
218.2 kip-ft

The two-way slab direct design calculator gives the total static moment M0 of a panel and its distribution to the negative and positive moments of an interior span and of an end span of a flat plate, using the ACI 318 fractions.

How the calculation works

  • Enter the factored load, the span in the direction of the moments, the width of the design strip and the column dimension.
  • The calculator finds the clear span and the total static moment M0.
  • It gives the negative and positive moments of an interior span and of an end span of a flat plate without edge beams.

Example

A flat plate carries a factored load of 250 psf on spans of 24 ft by 20 ft with columns of 20 in. The clear span is 24 − 20 / 12 = 22.33 ft. The total static moment is M0 = qu l2 ln² / 8 = 250 × 20 × 22.33² / 8 = 311.7 kip-ft. In an interior span, the negative moment is 0.65 M0 = 202.6 and the positive is 0.35 M0 = 109.1 kip-ft. In an end span, the moments are 0.26 M0 = 81.1, 0.52 M0 = 162.1 and 0.70 M0 = 218.2 kip-ft.

Why it matters

The calculator helps structural engineers, students and detailers to make a first estimate of the moments in a flat plate or a flat slab, to size the reinforcement and to check the results of a frame analysis or a program.

Good to know

Use the factored load of the load combination that governs, usually 1.2 times the dead load plus 1.6 times the live load. Take l2 as the average of the transverse spans on each side of the line of columns, and l1 as the span center to center of the supports. The method applies only if the panels are rectangular, with at least three spans in each direction, with spans that do not differ by more than one third, and with a live load not more than twice the dead load. After the moments, check the punching shear at the columns, which usually governs the thickness of a flat plate.

The rebar development length calculator gives the anchorage of bars, the shear friction calculator checks a crack, the composite metal deck calculator gives the concrete of a deck and the load combinations calculator gives the factored loads.

Frequently asked questions

What is the direct design method?

The direct design method of ACI 318 is a way to find the moments in a two-way slab with columns on a regular grid, without a frame analysis. It finds the total static moment of a panel in each direction and splits it into negative and positive moments with fixed fractions, which are then shared between the column strips and the middle strips.

What is the total static moment?

The total static moment is M0 = qu l2 ln² / 8, as for a simple beam with the span ln, the clear span between the faces of the supports, and the width l2. The clear span is not taken to be less than 0.65 times the span. The sum of the negative and positive moments of a span in one direction must equal M0.

What are the fractions?

For an interior span, 65 % of M0 is the negative moment at the supports and 35 % is the positive moment at midspan. For an end span of a flat plate without edge beams, the fractions are 0.26 M0 for the exterior negative moment, 0.52 M0 for the positive moment and 0.70 M0 for the interior negative moment.

What does the calculator leave out?

The calculator leaves out the distribution to the column and middle strips, the limits of the method for the regularity of the spans and the loads, the edge beams and the other end conditions of the table, the effect of the live load patterns, the shear and the punching at the columns and the minimum thickness. Check all of them with ACI 318.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.