Skip to content
Omnikalc

Wind pressure on cladding calculator: design suction and fastener force on roof and wall components

Enter the wind speed, the building height, the exposure, the zone coefficient and the tributary area to get the exposure coefficient, the velocity pressure, the design suction and the force on a fastener or panel.

Updated on
Your inputs
mph

Value out of range

ft

Value out of range

ft²

Value out of range

Results

Design suction on the cladding

53.1 psf

Velocity pressure exposure coefficient Kz
0.98
Velocity pressure at the roof height
28.3 psf
Force on the fastener or panel
531 lb

The wind pressure on cladding calculator gives the design suction on the components and cladding of a building with the ASCE 7 approach, from the wind speed, the height, the exposure and the zone, with the force on a fastener or on a panel from its tributary area.

How the calculation works

  • Enter the basic wind speed of the site, the mean roof height and the exposure category of the terrain.
  • Choose the zone of the building and its external pressure coefficient (GCp), which is higher at the edges and the corners than in the field.
  • Enter the tributary area of the fastener, the clip or the panel.
  • The calculator finds the exposure coefficient Kz, the velocity pressure, the design suction with the internal pressure of an enclosed building (GCpi = 0.18) and the force on the element.

Example

A building of 30 ft of height in Exposure C has a basic wind speed of 115 mph. The exposure coefficient is Kz = 2.01 × (30 / 900)^(2/9.5) = 0.98. The velocity pressure is 0.00256 × 0.98 × 0.85 × 115² = 28.3 psf. In the roof field zone with GCp = 1.7, the design suction is 28.3 × (1.7 + 0.18) = 53.1 psf, and a fastener with a tributary area of 10 ft² must resist 531 lb.

Why it matters

The calculator helps roofers, façade designers, building envelope consultants, contractors and students to estimate the wind load on the roof sheathing, the panels and their fasteners, to see how the edge and corner zones need more fasteners and to compare the effect of the wind speed and of the exposure. It gives an order of magnitude before the detailed calculation.

Good to know

Use the design wind speed and the exposure of the project, and the pressure coefficients for the real geometry from the code. Increase the fastening at the roof edges and the corners. Check the resistance of the fasteners with the manufacturer’s tests, and include the effect of the internal pressure of a building with large openings.

The wind load calculator gives the force on a sign or a panel, the wind shear power law calculator gives the wind speed at another height, the snow load calculator gives the roof snow load and the load combinations calculator combines the loads.

Frequently asked questions

What are components and cladding?

Components and cladding are the elements that receive the wind load directly and pass it to the structure: roof sheathing, shingles, roof panels, windows, doors, wall cladding and their fasteners. They are designed for the local pressures, which are much higher than the average pressures on the whole building, particularly at the roof edges, the ridges and the corners, where the wind creates strong suction.

How is the design pressure found in ASCE 7?

The velocity pressure at the mean roof height is qh = 0.00256 Kz Kzt Kd Ke V² in psf, with V in mph. The design pressure on a component is p = qh (GCp − GCpi), where GCp is the external pressure coefficient of the zone and the area, and GCpi the internal pressure coefficient, ±0.18 for an enclosed building. The calculator uses Kzt = 1, Kd = 0.85 and Ke = 1.

How does the exposure change the pressure?

The terrain upwind of the site slows the wind near the ground. Exposure B, urban areas, has the lowest pressure at a given height, Exposure C, open terrain, has a higher pressure and Exposure D, flat coastal areas, the highest. The coefficient Kz also increases with the height above the ground, which is why the roof of a tall building is more loaded than that of a low one.

What are the limits of the calculator?

The coefficients GCp of the calculator are typical values for small effective areas, and they change with the shape of the roof, its slope, the height of the building and the effective area of the element. The topographic effect Kzt, the wind directionality and the importance of the building are simplified. The values of the standard of the project, ASCE 7 or the local code, govern, and the cladding system should be designed by a qualified person.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.