Skip to content
Omnikalc

Wood shear wall deflection calculator with the four-term equation

Enter the load, the size of the wall, the end posts, the sheathing stiffness and the slip of the nails and the anchor to get the deflection and the drift.

Updated on
Your inputs
lb

Value out of range

ft

Value out of range

ft

Value out of range

psi

Value out of range

in²

Value out of range

kip/in

Value out of range

in

Value out of range

in

Value out of range

%

Value out of range

Results

Total deflection of the wall

0.556 in

Unit shear in the wall
325 lb/ft
Bending of the wall as a cantilever
0.0099 in
Shear deformation of the sheathing
0.186 in
Nail slip
0.240 in
Anchor slip and rotation
0.120 in
Drift as a percentage of the height
0.579 %
Drift to allowable drift
0.29
The drift is well within the limit

The wood shear wall deflection calculator adds the bending, the shear, the nail slip and the anchor slip of the four-term equation and compares the drift with the allowable drift.

How the calculation works

  • Enter the lateral load, the length and the height of the wall.
  • Enter the modulus and the cross-section of the end posts, the stiffness of the sheathing, the nail slip and the anchor slip.
  • The calculator gives the four terms of the deflection, the total deflection and the drift compared with the allowable drift.

Example

A wood shear wall 8 ft long and 8 ft high carries 2,600 lb, a unit shear of 325 lb/ft. The end posts have a section of 10.5 in² and a modulus of 1,600,000 psi, the sheathing has a stiffness of 14 kip/in, and the nail slip is 0.04 in and the anchor slip 0.12 in. The four terms are 0.0099 in for bending, 0.186 in for shear, 0.240 in for the nails and 0.120 in for the anchor. The total deflection is 0.556 in, a drift of 0.579 % of the height, or 0.29 of the 2 % limit.

Why it matters

The calculator helps structural engineers, framers and students to estimate how much a wood shear wall moves under a lateral load, to see which term dominates and to find out whether a longer wall, a stiffer sheathing or a better anchor is the best fix.

Good to know

Look at the largest term first. In a short, tall wall the bending and the anchor slip dominate, so use bigger end posts and a stiff hold-down anchor. In a long wall the nail slip dominates, so use closer nail spacing or thicker sheathing. Keep the anchor bolts tight and check the posts for shrinkage, and compare the drift with the limit of the wall above and the finishes.

The shear wall hold-down calculator gives the demand and the uplift at the ends, the sheathing nail schedule calculator gives the nail count, the hurricane tie-down calculator gives the uplift force of a roof and the wood beam span calculator checks a wood beam.

Frequently asked questions

What are the four terms?

The deflection of a wood shear wall is the sum of four parts, δ = 8 v h³ / (E A b) + v h / (1000 Ga) + 0.75 h en + h Δa / b. The first is the bending of the wall as a cantilever, carried by the end posts. The second is the shear deformation of the sheathing. The third is the slip of the nails, and the fourth is the rotation of the wall caused by the slip of the hold-down anchor.

Where do the stiffness values come from?

The apparent shear stiffness Ga of the sheathing and the nail slip en come from the tables of the wood standard for the panel type, the nail size and the spacing, or from the manufacturer for prefabricated walls. The nail slip depends on the unit shear, so it is read for the actual load. The anchor slip comes from the tests of the hold-down device at the load it carries.

What drift limit applies?

The allowable drift depends on the load and the code. For seismic design, story drift limits are around 2 % of the height for ordinary buildings, while a wind drift of the height divided by 360 to 500 protects finishes. Use the limit of your code and the load level for which the stiffness values are given, and note that the equation is for an allowable stress design load level.

What does the calculator leave out?

The calculator treats a single fully sheathed wall segment with a uniform nailing and an anchor at each end. It leaves out the openings, the perforated shear wall method, the effect of the gravity load, the stiffness of the story above and the rotation of the foundation. A wall with large openings or a flexible diaphragm needs a full analysis.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.