The hurricane tie-down calculator gives the tributary area, the gross wind uplift, the resisting dead load, the net design uplift and the ratio to the connector capacity at the support of a roof truss or rafter, with the ASD load combination of ASCE 7.
How the calculation works
- Enter the wind uplift pressure on the roof, the spacing and the span of the trusses or rafters, and the dead load of the roof.
- Enter the allowable uplift capacity of the connector (hurricane tie, strap or anchor) from the manufacturer’s table.
- The calculator finds the tributary area of one support, the gross uplift, the dead load that resists it, the net design uplift with the ASD combination 0.6 W − 0.6 D and the ratio to the capacity.
Example
A roof truss spans 28 ft at 2 ft spacing, with a wind uplift of 30 psf and a dead load of 12 psf. Each support has a tributary area of 2 × 28 / 2 = 28.0 ft². The gross uplift is 30 × 28 = 840 lb, and the dead load is 12 × 28 = 336 lb. The net uplift is 0.6 × (840 − 336) = 302 lb. A connector with an allowable capacity of 550 lb has a ratio of 302 / 550 = 0.55.
Why it matters
The calculator helps builders, designers, inspectors, home owners in hurricane regions and students to check the connection between the roof framing and the wall, to compare the uplift with the table value of a connector and to see the effect of the spacing and the span.
Good to know
Use the uplift pressure of the right roof zone, higher at the corners and the edges, and check the whole load path down to the foundation. Install the connectors with all the nails required, and use the corrosion resistant fasteners. Add the overhang uplift to the end connection.
Related tools
The wind load calculator gives the wind pressure, the load combinations calculator gives the combination factors, the wind cladding pressure calculator gives the component pressures and the roof truss calculator checks the truss geometry.