Skip to content
Omnikalc

Hurricane tie-down calculator: uplift force on the connection of a roof truss to the wall

Enter the wind uplift pressure, the truss spacing and span, the roof dead load and the capacity of the connector to get the tributary area, the gross uplift, the resisting dead load, the net uplift and the ratio.

Updated on
Your inputs
psf

Value out of range

ft

Value out of range

ft

Value out of range

psf

Value out of range

lb

Value out of range

Results

Net design uplift (0.6 W − 0.6 D)

302 lb

Tributary area of one support
28.0 ft²
Gross wind uplift
840 lb
Dead load resisting the uplift
336 lb
Demand to capacity ratio of the connector
0.55
The connector has enough capacity

The hurricane tie-down calculator gives the tributary area, the gross wind uplift, the resisting dead load, the net design uplift and the ratio to the connector capacity at the support of a roof truss or rafter, with the ASD load combination of ASCE 7.

How the calculation works

  • Enter the wind uplift pressure on the roof, the spacing and the span of the trusses or rafters, and the dead load of the roof.
  • Enter the allowable uplift capacity of the connector (hurricane tie, strap or anchor) from the manufacturer’s table.
  • The calculator finds the tributary area of one support, the gross uplift, the dead load that resists it, the net design uplift with the ASD combination 0.6 W − 0.6 D and the ratio to the capacity.

Example

A roof truss spans 28 ft at 2 ft spacing, with a wind uplift of 30 psf and a dead load of 12 psf. Each support has a tributary area of 2 × 28 / 2 = 28.0 ft². The gross uplift is 30 × 28 = 840 lb, and the dead load is 12 × 28 = 336 lb. The net uplift is 0.6 × (840 − 336) = 302 lb. A connector with an allowable capacity of 550 lb has a ratio of 302 / 550 = 0.55.

Why it matters

The calculator helps builders, designers, inspectors, home owners in hurricane regions and students to check the connection between the roof framing and the wall, to compare the uplift with the table value of a connector and to see the effect of the spacing and the span.

Good to know

Use the uplift pressure of the right roof zone, higher at the corners and the edges, and check the whole load path down to the foundation. Install the connectors with all the nails required, and use the corrosion resistant fasteners. Add the overhang uplift to the end connection.

The wind load calculator gives the wind pressure, the load combinations calculator gives the combination factors, the wind cladding pressure calculator gives the component pressures and the roof truss calculator checks the truss geometry.

Frequently asked questions

Why are hurricane ties needed?

Strong winds create a suction on the roof that tries to lift it from the walls. The roof is held down by its own weight and by the connections, so a continuous load path from the roof to the foundation is needed. The first connection in this path is the hurricane tie, or a strap or an anchor, which connects each truss or rafter to the top plate of the wall. Many roofs fail in the storms because of the weak connections.

How is the net uplift found?

The uplift on one support is the wind uplift pressure times the tributary area of the support, which is the truss spacing times half the span. The dead load of the roof resists a part of it. With the allowable stress design combination of ASCE 7, 0.6 D + 0.6 W, the net uplift is 0.6 times the wind uplift minus 0.6 times the dead load, and the result cannot be negative. The pressure comes from the wind analysis of the roof, with the zones for the edges and the corners.

What pressure should be used?

The uplift pressure depends on the wind speed, the exposure, the height, the roof slope and the zone of the roof. The pressures near the edges, the corners and the overhangs are much higher than in the field of the roof. The overhang also adds an uplift on the truss end. The pressure is found with the components and cladding procedure of ASCE 7, or with the tables of the residential codes such as the ICC 600 or the WFCM.

What are the limits of the calculator?

The calculator is a first check of one connector. It does not give the wind pressure, the effect of the overhangs and the different zones, the lateral loads on the connection, the load path from the top plate to the foundation, the capacity of the wall studs and of the anchors, or the code requirements for the hurricane regions. The connections must be selected and checked by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.