Skip to content
Omnikalc

Enlarger exposure calculator: how long for the new print size?

Enter a test exposure, the old and new enlarger height and the old and new aperture to get the new exposure time for your darkroom print.

Updated on
Your inputs
s

Value out of range

Value out of range

Value out of range

f/

Value out of range

f/

Value out of range

Results

New exposure time

42.5 s

Factor from the new height
2.250
Factor from the new aperture
1.891
Change in stops
2.09
Extra seconds per third of a stop
11.1 s

Changing the print size in a darkroom changes the exposure, and guessing wastes paper. This enlarger exposure calculator takes the test time, the old and new head heights and the old and new apertures to give the new exposure time, the factor from the height, the factor from the aperture, the change in stops and the extra seconds per third of a stop for your test strips.

How the calculation works

  • Height factor = (new height ÷ old height)². Light spreads over the square of the distance, so doubling the height of the enlarger head gives a print with a quarter of the light per area, and four times the exposure.
  • Aperture factor = (new f-number ÷ old f-number)². Going from f/8 to f/11 is one stop smaller, which doubles the time. The f-number squared is proportional to the inverse of the light.
  • New time = test time × height factor × aperture factor.
  • Change in stops = log₂(new time ÷ test time). Extra seconds per third of a stop = new time × (2^(1/3) − 1), useful for the steps of a test strip.

Example

Your test print took 10 s at a head height of 16 in and f/8. You raise the head to 24 in for a bigger print and stop down to f/11. The height factor is (24 ÷ 16)² = 2.25 and the aperture factor is (11 ÷ 8)² = 1.891. The new time is 10 × 2.25 × 1.891 ≈ 42.5 s, which is 2.09 stops more. A third of a stop is about 11.1 s at that setting.

Why it matters

Black-and-white printing is still loved by photographers, and paper and chemicals are costly. A good estimate gets you close to the right exposure in the first print, so you spend your time on dodging, burning and contrast and not on tests.

Good to know

The calculator assumes the same negative, paper, filtration and developer. Changing the paper grade or a variable-contrast filter also changes the time, so make a new test when you do. Enlarger lamps need a few seconds to warm up, so a very short time is unreliable. Under a long time, an aperture that is one stop wider halves the time and keeps the exposure the same, though lenses are sharpest a couple of stops down.

The exposure value calculator links aperture, shutter speed and ISO, the ND filter calculator converts stops into shutter speeds and the depth of field calculator relates the aperture to sharpness.

Frequently asked questions

Why does the exposure grow with the height?

The light of the enlarger spreads over a bigger area as the head goes up. The area grows with the square of the distance, so the same light covers more paper and each part gets less. To keep the same density, the time must grow with the square of the height ratio. The lens extension also adds a small effect, which this rule ignores.

Is the rule exact?

It is a good approximation for the usual range of print sizes. At large magnifications the lens extension is significant and the true change is slightly larger than the inverse square law says, so it is wise to make a new test strip. The calculator gives a start, not a final time.

What is an f-stop worth in time?

Each full stop of aperture, such as going from f/8 to f/11, halves the light, so you double the time. A third of a stop multiplies the time by about 1.26, and a half stop by 1.41. Many enlarger timers and timing tools work in stops, so the stops output helps you to set them.

How do I make a test strip?

Expose a strip of paper in steps, for example by covering more of the strip every few seconds or by raising the time by a third of a stop between steps. Develop it, pick the step with the best tones and use that as your test time here. The extra seconds per third of a stop gives the step size at the new setting.