Skip to content
Omnikalc

Indoor CO₂ ventilation calculator: CO₂ concentration, air per person and time to build up

Enter the people, their activity, the room volume and the outdoor airflow to get the steady-state CO₂ concentration in ppm, the air per person, the air changes per hour and the build-up time.

Updated on
Your inputs

Value out of range

ft³

Value out of range

cfm

Value out of range

ppm

Value out of range

Results

Steady-state indoor CO₂ concentration

1,522 ppm

Poor: strong need for more fresh air
Rise above the outdoor level
1,102 ppm
Outdoor air per person
10.0 cfm
Air changes per hour
1.60
Time to reach 90 % of the steady-state level
1.44 h

The CO₂ level of a room shows how well it is ventilated. The indoor CO₂ ventilation calculator gives the steady-state concentration from the number of people, their activity, the room volume and the outdoor airflow, with the air per person, the air changes per hour and the time the CO₂ takes to build up.

How the calculation works

  • Enter the number of people in the room and choose their activity level, which sets how much CO₂ each person breathes out.
  • Enter the volume of the room and the outdoor airflow that enters it (windows, a ventilation system or both).
  • Enter the outdoor CO₂ level, about 420 ppm today.
  • The calculator gives the steady-state CO₂ concentration: outdoor level + CO₂ produced / airflow, the air per person, the air changes per hour and the time to reach 90 % of the steady-state level.

Example

Four people sit in a room of 1,500 ft³ (12 × 16 × 8 ft) with 40 cfm of outdoor air, which is 18.9 L/s. They produce 4 × 0.0052 = 0.0208 L/s of CO₂, so the level rises by 0.0208 / 18.9 = 1,102 ppm above the outdoor 420 ppm, to 1,522 ppm in steady state. This is 10 cfm per person and 1.6 air changes per hour, and it takes about 1.4 hours to reach 90 % of that level. The room needs more ventilation.

Why it matters

The calculator helps teachers, office managers, parents, remote workers and anyone with a CO₂ monitor to understand the numbers, to plan how much to ventilate a bedroom, a classroom or a meeting room and to see how many people a room can host with a given airflow. It makes the link between the CO₂ level and the fresh air supply.

Good to know

The calculator assumes that the air in the room is well mixed, that the outdoor CO₂ and the ventilation are constant and that the CO₂ comes only from people. Real rooms have gaps in the mixing, variable airflow, other sources such as gas stoves, and a CO₂ level that changes with the time of day. The generation rates are averages for adults, and children produce less. Use the result as an estimate.

The air changes calculator finds the rate of a room, the minute ventilation calculator concerns the breathing of a person, the CO₂ breathing calculator looks at the exhaled CO₂, and the AC size calculator sizes cooling for a room.

Frequently asked questions

Why does the CO₂ level in a room rise?

People breathe out CO₂, about 0.005 liters per second for an adult seated, and the CO₂ stays in the room if the ventilation is low. Outdoors the level is about 420 ppm. Indoors it climbs until the CO₂ leaving with the ventilated air equals the CO₂ produced. This steady-state level depends only on the number of people, their activity and the outdoor airflow per person, and not on the size of the room, which only changes how fast it gets there.

What CO₂ level is considered acceptable?

A level under 800 ppm is generally regarded as a well-ventilated space. Standards such as ASHRAE often refer to about 700 ppm above the outdoor level, that is about 1,100 ppm, as a sign of a ventilation of about 7.5 to 10 L/s per person. Above 1,500 ppm many people feel the air stuffy, and some studies find a loss of concentration at 1,000 to 2,500 ppm. CO₂ at these levels is not toxic, but it is a good marker of poor ventilation.

How much air per person do I need?

A common target is 7.5 to 10 L/s per person (about 15 to 20 cfm, or 27 to 36 m³/h) for offices and classrooms, which keeps the CO₂ near 1,000 ppm. A bedroom for one sleeping person needs less because of the lower production of CO₂, but a closed room can still reach high values in a night. The calculator shows how the steady-state value falls when the airflow rises.

Is a CO₂ meter useful?

Yes. A CO₂ monitor shows the real level in the room and helps you decide when to open a window or to raise the ventilation. The reading is also a proxy for the risk of respiratory infections, because the air breathed out by others accumulates in the same way. The meters need calibration, and the readings change with the position, so use the calculator for planning and a meter for checking.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.