ASHRAE 62.2 ventilation rate calculator: required mechanical ventilation for a house

Enter the floor area, the number of bedrooms and an infiltration credit to get the ASHRAE 62.2 total ventilation rate in cfm, the airflow still needed and the equivalent air changes per hour.

Updated on
Your inputs
sq ft

Value out of range

Value out of range

cfm

Value out of range

ft

Value out of range

Results

Total required ventilation rate

90.0 cfm

Mechanical ventilation airflow still needed
90.0 cfm
Required rate in liters per second
42.5 L/s
Air changes per hour from the required rate
0.34
Typical range for a ventilated home

ASHRAE 62.2 sets the minimum whole-house ventilation for homes from the floor area and the number of bedrooms. The residential ventilation rate calculator gives the required airflow in cfm and L/s, the airflow that mechanical ventilation must still supply after an infiltration credit, and the equivalent air changes per hour.

How the calculation works

  • Enter the conditioned floor area of the home and its number of bedrooms. The calculator assumes one more occupant than bedrooms.
  • Enter an infiltration credit if you have a tested value for the air leakage of the home, otherwise leave it at zero.
  • Enter the average ceiling height to get the air changes per hour.
  • The calculator applies the ASHRAE 62.2 equation: 0.03 cfm per sq ft plus 7.5 cfm per occupant (bedrooms + 1), and gives the total rate and the mechanical airflow still needed.

Example

A home of 2,000 sq ft with 3 bedrooms has 4 assumed occupants. The required rate is 0.03 × 2,000 + 7.5 × 4 = 60 + 30 = 90 cfm, which is 42.5 L/s. With no infiltration credit, the mechanical airflow is also 90 cfm. For a ceiling height of 8 ft, the volume is 16,000 ft³ and the rate corresponds to 0.34 air changes per hour.

Why it matters

The calculator helps builders, energy auditors, HVAC contractors and homeowners to size a ventilation system, such as an HRV, an ERV or a continuous exhaust fan, in a new home or after air sealing. It shows what airflow is needed to keep the indoor air healthy in a tight house.

Good to know

The calculator uses the equation of ASHRAE 62.2 from 2013 and later for single-family homes and low-rise multifamily dwellings. It does not include local exhaust requirements, the real number of occupants, the climate-based infiltration credit calculation, the balancing of the system or the local building code, which can differ. Check the code that applies to your project.

The attic ventilation calculator sizes the roof vents, the bathroom fan calculator sizes an exhaust fan, the air changes calculator finds the rate of a room, and the minute ventilation calculator concerns breathing and not buildings.

Frequently asked questions

What is ASHRAE 62.2?

ASHRAE Standard 62.2 gives the minimum ventilation rates and the other requirements for acceptable indoor air quality in low-rise residential buildings. It sets a whole-dwelling mechanical ventilation rate based on the floor area and the number of bedrooms, and also requires local exhaust in kitchens and bathrooms. Many US energy codes, programs and building codes refer to it.

How is the required rate computed?

In the version of 2013 and later, the total ventilation rate in cfm is 0.03 times the floor area in square feet plus 7.5 times the number of bedrooms plus one. In metric units, it is 0.15 liters per second per square meter plus 3.5 liters per second per occupant. The number of occupants is assumed to be the number of bedrooms plus one, whatever the real number of people.

What is the infiltration credit?

Air leaks through the envelope also bring fresh air, and ASHRAE 62.2 allows to subtract a part of that leakage from the required mechanical rate when the home is not very tight and the leakage is measured by a blower door test. The credit depends on the climate, the height and the leakage. If you do not have a test, use zero, which is on the safe side.

Do I still need exhaust fans in the kitchen and the bathrooms?

Yes. The whole-house rate is for the general dilution of the pollutants, and the local exhaust removes moisture, odors and cooking pollutants at the source. ASHRAE 62.2 also sets minimum rates for these fans, for example 100 cfm intermittent or 5 air changes per hour continuous in kitchens, and 50 cfm intermittent or 20 cfm continuous in bathrooms.