Spectacle magnification and aniseikonia calculator

Enter the back vertex power, the front surface power, the center thickness, the index and the vertex distance of a lens to get the shape factor, the power factor, the spectacle magnification and the difference in image size with the other eye.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
D

Value out of range

D

Value out of range

mm

Value out of range

Value out of range

mm

Value out of range

%

Value out of range

Results

Spectacle magnification

9.90 %

A clear change in image size
Shape factor
1.0331
Power factor
1.0638
Aniseikonia (difference in size between the eyes)
1.90 %
A difference of 1 % or more can cause symptoms such as headaches and distortion

The spectacle magnification calculator gives the shape factor, the power factor, the spectacle magnification and the aniseikonia between the two eyes from the power, the front surface, the thickness, the index and the vertex distance.

How the calculation works

  • Enter the back vertex power and the front surface power.
  • Enter the thickness, the index and the vertex distance.
  • Enter the other lens and read the aniseikonia.

Example

A lens of +5.00 D with a front surface of +8.00 D, a thickness of 6 mm and an index of 1.5, worn at 12 mm, has a shape factor of 1 / (1 − 0.006 / 1.5 × 8) = 1.0331 and a power factor of 1 / (1 − 0.012 × 5) = 1.0638. The spectacle magnification is 9.90 %. If the other lens has 8 %, the aniseikonia is 1.90 %.

Why it matters

The calculator helps optometry and ophthalmology students, opticians and clinicians who see a patient with different prescriptions in the two eyes, for example after cataract surgery in only one eye.

Good to know

The relative spectacle magnification compares the corrected eye with a standard emmetropic eye, and the size of the image in an axially long or short eye differs from that of a normal eye even with no lens, which is why the axial or refractive nature of the anisometropia matters. Knapp law states that an axial anisometropia is best corrected with the lens placed at the front focal plane of the eye, about 15 millimeters in front of the cornea, which gives equal image sizes in the two eyes, whereas a refractive anisometropia is best corrected by contact lenses. The calculator uses the thick lens formula for the central part of a lens and does not model astigmatism, which stretches the image in one meridian. A diagnosis of aniseikonia is made with dedicated tests such as the space eikonometer, and the prescription of lenses is decided by the eye care professional.

The Prentice calculator treats the induced prism, the lens thickness calculator estimates the edge thickness, the vertex distance calculator converts the power and the IOL power calculator treats an implant.

Frequently asked questions

What is spectacle magnification?

It is the ratio of the size of the retinal image with the lens to the size without it, for a corrected eye. It is the product of the shape factor, which depends on the thickness and the front curve, and the power factor, which depends on the power and the vertex distance.

What is aniseikonia?

It is a difference in the size or the shape of the images seen by the two eyes. It often follows a large difference in power between the eyes, called anisometropia, and about 1 % of difference in size is a common threshold for symptoms.

How can it be reduced?

Contact lenses and intraocular lenses reduce it, because they sit near the eye. In glasses, the vertex distance, the thickness and the base curve can be changed, but only within limits, and size lenses (iseikonic lenses) are rarely used.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.