Skip to content
Omnikalc

Chromatographic resolution calculator

Enter the retention times and the base widths of two peaks and the dead time to get the resolution, the selectivity, the retention factors and the number of plates needed for a baseline separation.

Updated on
Your inputs
min

Value out of range

min

Value out of range

min

Value out of range

min

Value out of range

min

Value out of range

Results

Resolution

2.69

Baseline separation
Selectivity (α)
1.167
Retention factor of peak 1
4.20
Retention factor of peak 2
4.90
Plates needed for a resolution of 1.5
2,557

The chromatographic resolution calculator gives the resolution of two peaks, the selectivity, the retention factors and the number of plates needed for a baseline separation.

How the calculation works

  • Enter the retention times and the base widths of the two peaks.
  • Enter the dead time.
  • The calculator gives the resolution, the selectivity, the retention factors and the plates needed for Rs = 1.5.

Example

Two peaks elute at 5.2 and 5.9 min with base widths of 0.25 and 0.27 min. The resolution is 2 × 0.7 / 0.52 = 2.69. With a dead time of 1 min, the retention factors are 4.20 and 4.90, and the selectivity is 1.167. A resolution of 1.5 would need about 2,557 plates for this selectivity, much less than the column already provides.

Why it matters

The calculator helps chemistry students, analysts and method developers who judge a separation in liquid or gas chromatography and decide whether to change the column or the mobile phase.

Good to know

A resolution above 1.5 is the usual goal for quantitative work, and 2.0 gives a margin for variation. The widths must be measured in the same way for the two peaks, for example at the base by tangents. When the two peaks are of very different sizes, a larger resolution is needed, because the large peak’s tail hides the small one. The plates needed assume the two retention factors given here. For the best use, also keep the retention factor between 2 and 10, since below 1 the compounds elute too near the void time and above 10 the analysis is slow. Gradient elution changes the picture and calls for other formulas.

The plate number calculator gives the column efficiency, the Rf value calculator covers thin layer chromatography, the van Deemter calculator relates flow and plate height and the standard deviation calculator describes spread.

Frequently asked questions

How is the resolution defined?

Rs = 2 (t2 − t1) / (w1 + w2): the distance between the two peak maxima divided by the average base width. A value of 1.5 means that the peaks are separated down to the baseline, and 1.0 means about 2 % overlap.

What do retention factor and selectivity mean?

The retention factor k = (tR − t0) / t0 says how much longer a compound stays than an unretained one. The selectivity α = k2 / k1 compares the two compounds and has to exceed 1 to separate them. Changing the solvent or the column mainly changes α.

How can I improve a poor resolution?

The resolution depends on the plates, the selectivity and the retention: Rs = (√N / 4) × ((α − 1) / α) × (k2 / (1 + k2)). Raising N with a longer column or smaller particles helps only as the square root, so a better selectivity is usually more effective.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.