The flue gas tells how well a burner works. The combustion efficiency calculator uses the oxygen and the temperature of the flue gas to find the excess air, the stack loss and the combustion efficiency with the Siegert formula, for natural gas, heating oil or propane.
How the calculation works
- Select the fuel: natural gas, heating oil or propane. Each fuel has its own constants in the Siegert formula.
- Enter the oxygen measured in the flue gas with a combustion analyzer (dry basis) and the flue gas temperature, measured in the stack before any dilution.
- Enter the combustion air temperature, usually the temperature of the boiler room.
- The calculator gives the excess air O₂ / (21 − O₂), the stack loss and the combustion efficiency from the Siegert formula, and the gain that you would get by trimming the oxygen to 3%.
Example
A gas boiler shows 4.0% oxygen, a flue gas temperature of 350 °F and a combustion air temperature of 70 °F. The difference is 280 °F, or 155.6 K. The excess air is 4.0 / (21 − 4.0) = 23.5%. With the constants A2 = 0.66 and B = 0.009 for natural gas, the stack loss is 155.6 × (0.66 / 17 + 0.009) = 7.44%. The combustion efficiency is 100 − 7.44 = 92.6%. Trimming the oxygen to 3% would reduce the loss by 0.34 points.
Why it matters
The calculator helps heating technicians, energy auditors, homeowners and students to read a combustion analysis, to see how much a burner adjustment can save and to compare the readings before and after a tune-up. It turns two numbers of the analyzer into a clear efficiency.
Good to know
Measure after the appliance has run for several minutes, with the probe in the center of the flue. Keep the oxygen high enough to avoid carbon monoxide. A flue gas temperature that is much higher than usual shows dirty heat exchange surfaces. Do not lower the temperature of a non-condensing appliance below the dew point of the flue gas, since the condensate is corrosive.
Related tools
The heat of combustion calculator gives the energy of a fuel, the boiler size calculator sizes the heat source, the chimney height calculator covers the flue and the dew point calculator helps to avoid condensation in the stack.