Skip to content
Omnikalc

DC motor torque and back EMF calculator

Enter the supply voltage, the winding resistance, the torque constant and the load torque to get the current, the speed, the power and the efficiency.

Updated on
Your inputs
V

Value out of range

Ω

Value out of range

N·m/A

Value out of range

N·m

Value out of range

Results

Speed under load

3,896 rpm

Armature current
3.00 A
Back EMF
20.4 V
Mechanical power
61.2 W
Efficiency
85.0 %
Stall torque
1.00 N·m
Ideal no-load speed
4,584 rpm

The DC motor calculator gives the armature current, the back EMF, the speed under load, the mechanical power, the efficiency and the stall torque of a brushed DC motor.

How the calculation works

  • Enter the supply voltage, the armature resistance and the torque constant.
  • Enter the load torque the motor must deliver.
  • The calculator finds the current from the torque, the back EMF from the voltage drop in the winding, then the speed, the power and the efficiency.

Example

A motor on 24 V with an armature of 1.2 Ω and a torque constant of 0.05 N·m/A that drives a load of 0.15 N·m draws 3.00 A. The back EMF is 20.4 V, the speed 3,896 rpm and the mechanical power 61.2 W, for an efficiency of 85.0 %. The stall torque is 1.00 N·m and the ideal no-load speed 4,584 rpm.

Why it matters

The calculator helps students, robot builders, designers of small drives and anyone who selects a brushed DC motor for a pump, a fan, a winch or a wheel, and wants to know the current, the speed and the heating before the first test.

Good to know

The model is linear: the speed falls with the load and the current rises with the torque. Real motors have friction, so they draw a small current at no load, and their resistance rises with temperature, which lowers the stall torque when hot. Keep the continuous torque below the rated value on the data sheet, since the winding heat grows with the square of the current. A motor driven by a PWM controller sees the average voltage, so enter the average. If the load torque is close to the stall torque, the speed goes to zero, the efficiency collapses and the motor can burn. Add a current limit to protect the motor and the driver at start.

The motor current calculator gives the current drawn from the power and the voltage, the motor speed calculator gives the speed from the frequency and the poles, the horsepower and torque calculator converts between the two and the Ohm’s law calculator handles the winding.

Frequently asked questions

What is the back EMF of a DC motor?

A spinning armature acts as a generator and produces a voltage that opposes the supply: E = Ke × ω, where Ke is the back-EMF constant and ω the angular speed. In SI units Ke equals the torque constant Kt. The current is then (V − E) / R, so the motor draws a large current at start and a small one when it runs at no load.

How is the speed under load found?

The torque sets the current, I = T / Kt. The back EMF is E = V − I × R, and the speed is ω = E / Kt in radians per second, which is multiplied by 60 / (2 × π) to get revolutions per minute. A heavier load increases the current, lowers E and slows the motor, so the speed falls almost linearly with the torque.

What is the stall torque?

At standstill there is no back EMF, so the current is V / R and the torque is Kt × V / R, the largest the motor can produce. This current is many times the rated current and heats the winding quickly. The calculator shows it as a limit: the load torque must stay well below it, usually below a third.

Why is the efficiency not 100 %?

The electrical power V × I is split between the mechanical power T × ω and the copper loss I² × R in the winding. This model leaves out friction, iron losses and brush drop, so a real motor is a few points lower. Efficiency is best when the speed is close to the no-load speed and falls to zero at stall.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.