Enter the received frequency, the intermediate frequency, the side of the local oscillator and the Q of the input circuit to get the oscillator frequency, the image frequency and the image rejection.

Updated on
Your inputs
MHz

Value out of range

MHz

Value out of range

Value out of range

Results

Image frequency

119.500 MHz

Local oscillator frequency
108.800 MHz
Image rejection of a single tuned circuit
26.0 dB
Weak: add a filter or use a higher IF
Separation between signal and image
21.400 MHz
Separation as a share of the signal frequency
21.8 %

The image frequency calculator gives the local oscillator frequency, the image frequency and the image rejection of a superheterodyne receiver.

How the calculation works

  • Enter the received frequency and the intermediate frequency.
  • Pick the side of the local oscillator and enter the Q of the input circuit.
  • The calculator gives the image frequency, the oscillator frequency, the image rejection, the separation and its share of the signal frequency.

Example

To receive an FM station at 98.1 MHz with an IF of 10.7 MHz and high-side injection, the oscillator runs at 108.800 MHz and the image is at 98.1 + 2 × 10.7 = 119.500 MHz. With ρ = 0.397 and a Q of 50, a single tuned circuit rejects it by 26.0 dB. The separation is 21.400 MHz, or 21.8 % of the signal frequency.

Why it matters

The calculator helps radio amateurs, electronics students and engineers who design or repair receivers, scanners and tuners and who choose the intermediate frequency.

Good to know

Common intermediate frequencies are 455 kHz for AM broadcast, 10.7 MHz for FM broadcast and 45 to 70 MHz for many communication receivers, chosen to push the image far from the signal. Some receivers use a double conversion: a high first IF to reject the image, then a low second IF for selectivity. Image-reject mixers cancel the image by phase cancellation, achieving 20 to 40 dB. The rejection shown is for one tuned circuit, and several stages in a row add their rejections in decibels. Direct-conversion and software-defined receivers avoid the image problem with a zero or very low IF, at the cost of other issues.

The FM bandwidth calculator covers the signal width, the AM power calculator covers amplitude modulation, the thermal noise calculator estimates sensitivity and the RC filter calculator designs simple filters.

Frequently asked questions

What is the image frequency?

A superheterodyne receiver mixes the signal with a local oscillator to get a fixed intermediate frequency. A second frequency, on the other side of the oscillator and at the same distance, produces the same intermediate frequency. This unwanted frequency is the image, 2 × IF away from the signal.

How is the image rejected?

By a filter before the mixer. A single tuned circuit of quality factor Q rejects the image by √(1 + Q²ρ²), where ρ = f_image / f_signal − f_signal / f_image. A higher intermediate frequency moves the image further away and makes the filter’s job easier.

High-side or low-side injection?

High-side injection puts the oscillator above the signal and is common because it needs a smaller tuning ratio. Low-side injection puts it below. The image falls on the other side of the oscillator in each case, and it must stay above zero frequency.

Was this calculator helpful?