Skip to content
Omnikalc

Optical fiber V-number and mode count calculator

Enter the core radius, the numerical aperture and the wavelength to get the V-number, the number of modes and the single-mode cutoff wavelength.

Updated on
Your inputs
µm

Value out of range

Value out of range

nm

Value out of range

Results

V-number

36.96

Modes in a step-index fiber
683
Modes in a graded-index fiber
342
Single-mode cutoff wavelength
13.06 µm
Acceptance half-angle in air
11.5 °

The optical fiber V-number calculator gives the V-number, the number of modes in a step-index and a graded-index fiber, the single-mode cutoff wavelength and the acceptance angle.

How the calculation works

  • Enter the core radius in micrometres and the numerical aperture of the fiber.
  • Enter the operating wavelength.
  • The calculator gives V = 2 × π × a × NA / λ, then the approximate number of guided modes and the cutoff wavelength for single-mode operation.

Example

A fiber with a core radius of 25 µm and a numerical aperture of 0.2 has a V-number of 36.96 at 850 nm. It guides about 683 modes with a step index or 342 with a graded index. It would be single-mode only above 13.06 µm, and light enters it within a half-angle of 11.5 ° in air.

Why it matters

The calculator helps network engineers, photonics students and installers who need to know whether a fiber is single-mode or multimode at a given wavelength, and how many modes will carry the signal in a short-reach link.

Good to know

The mode count formulas are approximations that hold for large V. Near the single-mode limit, use the exact value of 2.405 and the data sheet of the fiber. The cutoff wavelength given by manufacturers is measured on a 2 m sample and is lower than the theoretical value, because bends strip the higher modes. Multimode fibers are used for short links in buildings and data centers with 850 nm sources, while single-mode fibers are used for long links at 1 310 and 1 550 nm. Match the fiber to the transceiver: a single-mode transceiver needs a single-mode fiber, and a multimode source on a single-mode fiber loses most of its power. Clean connectors and check the bend radius.

The optical link budget calculator checks the loss of a link, the waveguide cutoff calculator treats the electromagnetic version of the same problem, the critical angle calculator gives the limit of total reflection and the photon energy calculator relates the wavelength to the energy.

Frequently asked questions

What is the V-number of a fiber?

The V-number, or normalized frequency, is V = 2 × π × a × NA / λ, where a is the core radius, NA the numerical aperture and λ the wavelength. It sums up the geometry and the light in one number. A step-index fiber is single-mode when V is below 2.405, the first zero of the Bessel function, and multimode above.

How many modes does a fiber carry?

For a large V the number of guided modes is about V² / 2 in a step-index fiber and about V² / 4 in a graded-index fiber. A 50 µm core fiber with an NA of 0.2 at 850 nm has a V of about 37 and carries roughly 680 modes in a step-index design, or 340 with a graded index. Each mode travels at a slightly different speed, which causes modal dispersion.

What is the cutoff wavelength?

A fiber is single-mode only above its cutoff wavelength λc = 2 × π × a × NA / 2.405. A standard single-mode fiber with a core of 4.1 µm radius and an NA of 0.12 has a cutoff near 1.3 µm, which is why it is single-mode at 1 310 and 1 550 nm and slightly multimode at 850 nm.

What is the numerical aperture?

The numerical aperture NA = √(ncore² − nclad²) sets the acceptance cone of the fiber, with the half-angle asin(NA) in air. A higher NA collects more light and bends more tightly, but also guides more modes and gives more dispersion. Typical values are 0.1 to 0.14 for single-mode fiber and 0.2 to 0.27 for multimode fiber.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.