The Pockels cell calculator gives the half-wave voltage, the retardation at an applied voltage, the transmission between crossed polarizers, the quarter-wave voltage, the index factor n³r and the retardation per 100 V for three common crystals.
How the calculation works
- Choose the crystal and geometry.
- Enter the wavelength, and for the transverse cell the length and the thickness.
- Enter the applied voltage to get the retardation and the transmission.
Example
At 1550 nm nm the crystal has a half-wave voltage of 256.7 V, a quarter-wave voltage of 128.4 V and 70.11 ° of retardation per 100 V. At 130 V V the retardation is 91.1 ° and the transmission between crossed polarizers is 0.510.
Why it matters
The calculator helps students of photonics and laser engineers who choose a crystal and a geometry for a switch or modulator, and who want a first estimate of the voltage a driver must supply.
Good to know
The values are for the main electro-optic coefficient and ordinary or extraordinary index of each crystal and for the field along its axis. Real cells have a natural birefringence that must be compensated, and the half-wave voltage varies with the wavelength and the temperature. The transmission formula applies to crossed polarizers at 45 degrees from the axes of the crystal, and the peak transmission at Vπ is ideal. A fast driver needs to charge the capacitance of the crystal, so a lower Vπ is only one part of a design. For pulse picking or Q-switching, the cell is usually set at the quarter-wave or half-wave voltage with a fast high-voltage driver, and the crystal is kept at a stable temperature to avoid drift.
Related tools
The waveplate thickness calculator sizes passive retarders, the polarizer extinction ratio calculator rates polarizers, the Faraday rotation calculator treats magneto-optic rotation and the photon energy calculator links wavelength and energy.