Radiation leaving a surface is not all caught by another one. The view factor calculator finds the fraction that arrives from the first coaxial disc to the second, from the radii and the distance. It also gives the reverse factor F₂₁ by reciprocity and the net radiation for black surfaces from the temperatures.
How the calculation works
- Enter the radius of each disc, the distance between them along the common axis and, if you want the heat flow, the two temperatures.
- The calculator takes R₁ = r₁/L, R₂ = r₂/L and S = 1 + (1 + R₂²) / R₁².
- The view factor from disc 1 to disc 2 is F₁₂ = ½ [S − √(S² − 4 (r₂/r₁)²)], the share of the radiation of disc 1 that reaches disc 2.
- The reciprocity rule A₁F₁₂ = A₂F₂₁ gives F₂₁, and the net exchange for black surfaces is Q = σ A₁ F₁₂ (T₁⁴ − T₂⁴).
Example
Two parallel discs of radii 4 in and 6 in face each other at a distance of 8 in. The view factor F₁₂ is 0.325, and F₂₁ is 0.144. With disc 1 at 500 °F and disc 2 at 100 °F, and with both taken as black surfaces, the net radiation is 42.7 W, which is 146 BTU/h.
Why it matters
View factors are the geometric part of every radiation heat transfer calculation: furnaces, radiant heaters, cooling of spacecraft, solar collectors, fire safety, ovens and the thermal design of lamps and electronics. Parallel coaxial discs are a standard case that has a closed-form solution and is used to check software.
Good to know
The calculator applies the exact formula for two directly opposed, coaxial, parallel discs in a transparent medium, with uniform radiosity on each. Surfaces that are not black, with an emissivity below 1, exchange less heat, and reflections from other surfaces are not included. The net radiation shown is for black surfaces and so is an upper bound on real surfaces. Misaligned or tilted discs need other formulas.
Related tools
The radiative heat exchange calculator adds the emissivities and the shields, the blackbody radiation calculator covers the Stefan–Boltzmann law for one surface, the heat loss calculator covers the total loss, and the natural convection calculator covers the other mode of transfer from a hot surface.