Skip to content
Omnikalc

Choked flow calculator: sonic mass flow, critical pressure ratio and throat conditions of a gas

Choose the gas and enter the upstream pressure and temperature, the diameter and the discharge coefficient to get the choked mass flow and the conditions at the throat.

Updated on
Your inputs
psia

Value out of range

°F

Value out of range

in

Value out of range

Value out of range

Results

Choked mass flow

0.1100 lb/s

Choked mass flow per hour
396 lb/h
Critical pressure ratio (throat / upstream)
0.5283
Highest back pressure that keeps the flow choked
52.8 psia
Gas temperature at the throat
-18.3 °F
Gas speed at the throat (speed of sound)
1,030 ft/s

Choked flow is the maximum flow of a gas through a nozzle or an orifice, reached when the gas moves at the speed of sound at the narrowest section. The choked flow calculator gives the mass flow, the critical pressure ratio, the highest back pressure for choking and the temperature and speed at the throat.

How the calculation works

  • Choose the gas: it sets the ratio of specific heats γ and the gas constant R (air 1.4, carbon dioxide 1.289, helium 1.667, methane 1.31).
  • Enter the upstream absolute pressure and temperature, the diameter of the orifice or the throat and the discharge coefficient.
  • The calculator gives the choked mass flow ṁ = Cd A P₀ √(γ / (R T₀)) × (2 / (γ + 1))^((γ + 1) / (2(γ − 1))), valid when the flow reaches the speed of sound at the throat.
  • It also gives the critical pressure ratio, the highest back pressure that keeps the flow choked, and the temperature and the speed of the gas at the throat.

Example

Air at 100 psia and 70 °F flows through a 0.25 in orifice with a discharge coefficient of 0.97. The throat area is 0.0491 in². The choked mass flow is 0.1100 lb/s, or 396 lb/h. The critical pressure ratio is 0.5283, so the flow stays choked while the back pressure is under 52.8 psia. At the throat, the gas cools to −18.3 °F and moves at 1,030 ft/s.

Why it matters

The calculator helps engineers, technicians and students to size relief valves, nozzles, gas leaks, vents, pneumatic systems and rocket nozzles, and to estimate the flow of a gas leak from a pressurized vessel. It shows right away if the flow is limited by the speed of sound, which simplifies many calculations.

Good to know

The formula assumes an ideal gas with constant specific heats, an isentropic flow up to the throat and a flow that is really choked, with a back pressure below the critical value. Real gases at high pressure, mixtures, the friction in a long pipe and the effect of the geometry are not included. For safety valves and relief systems, use the standards of your region and the data of the manufacturer.

The isentropic flow calculator gives the properties along a nozzle, the Mach number calculator relates speed and the speed of sound, the orifice flow calculator handles liquids and subsonic gas, and the normal shock relations calculator handles shocks downstream.

Frequently asked questions

What is choked flow?

A gas that flows through a nozzle or an orifice accelerates as the pressure drops. When the pressure downstream is low enough, the speed at the narrowest section reaches the speed of sound. The flow is then choked: the mass flow cannot increase any more, even if the downstream pressure is lowered further. It depends only on the upstream pressure and temperature.

When is the flow choked?

The flow is choked when the ratio of the downstream to the upstream absolute pressure is under the critical ratio (2 / (γ + 1))^(γ / (γ − 1)). For air this ratio is 0.528, so the upstream absolute pressure must be at least 1.89 times the downstream pressure. This is why a leak from a pressurized tank is limited to a fixed flow.

Why does the mass flow depend on the pressure and not on the downstream conditions?

At the throat the gas moves at the speed of sound, and pressure changes downstream travel at the same speed, so they cannot move upstream. The throat does not know the downstream pressure. The mass flow is then proportional to the upstream absolute pressure, so doubling it doubles the flow, and it falls with the square root of the temperature.

What is the discharge coefficient?

The discharge coefficient Cd corrects the ideal flow for the real shape of the orifice, for the friction and for the narrowing of the stream after a sharp edge. It is about 0.6 to 0.65 for a sharp-edged orifice and 0.95 to 0.99 for a well-rounded nozzle. Use the value of your device, since it changes the result a lot.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.