Skip to content
Omnikalc

Biaxial bending column Bresler reciprocal load calculator

Enter the axial capacity, the capacities for each eccentricity and the factored load to get the capacity in biaxial bending, the design capacity and the ratio.

Updated on
Your inputs
kip

Value out of range

kip

Value out of range

kip

Value out of range

kip

Value out of range

Value out of range

Results

Ratio of the load to the design capacity

0.81

The column can carry the load in biaxial bending
Nominal capacity with biaxial bending
954.5 kip
Design capacity
620.5 kip
Ratio of the capacity to the axial capacity
0.48

The biaxial bending column Bresler reciprocal load calculator gives the capacity in biaxial bending, the design capacity, the ratio of the load to the design capacity and the ratio of the capacity to the axial capacity of a reinforced concrete column, from the capacities with each eccentricity alone.

How the calculation works

  • Enter the axial capacity of the column with no eccentricity.
  • Enter the capacities with the eccentricity in each direction alone and the factored load.
  • The calculator finds the capacity in biaxial bending, the design capacity and the ratio.

Example

A column has an axial capacity of 2,000 kip, 1,400 kip with the eccentricity ex only and 1,200 kip with ey only. The reciprocal load gives 1 / Pn = 1 / 1,400 + 1 / 1,200 − 1 / 2,000, that is Pn = 954.5 kip. With a factor of 0.65, the design capacity is 620.5 kip. A factored load of 500 kip gives a ratio of 0.81. The capacity is 0.48 of the axial capacity.

Why it matters

The calculator helps structural engineers, checkers and students to make a quick check of a corner column or an edge column in biaxial bending, to see how the two eccentricities reduce the capacity, and to verify the result of a design program.

Good to know

Use the nominal capacities of the interaction diagram, without the reduction factor, and apply the factor at the end. Check that the load is more than 10 % of the axial capacity before using the method. For columns that are slender, add the moment magnification in each direction before reading the capacities. Compare the result with a second method or with the output of a design program, because the reciprocal load equation is an approximation and it can be unsafe in some cases.

The RC column axial capacity calculator gives the axial capacity, the punching shear calculator checks a slab at a column, the steel column capacity calculator checks a steel column and the Euler buckling calculator gives the critical load.

Frequently asked questions

What is the Bresler reciprocal load method?

The Bresler method gives the capacity of a column loaded with an eccentricity in two directions from the capacities of the same column with each eccentricity alone and with no eccentricity. The inverse of the capacity is the sum of the inverses of the two uniaxial capacities, minus the inverse of the axial capacity. The method is simple, and it is used by designers for a quick check of the columns in biaxial bending.

When is the method valid?

The method is valid when the axial load is at least 10 % of the axial capacity of the column, that is when the column is in compression-controlled or near the balanced point. For a small axial load, the column behaves like a beam in biaxial bending, and the method gives results which are too high and unsafe. The calculator shows the ratio of the capacity to the axial capacity, so that you can check this limit.

How are the uniaxial capacities found?

The capacity with the eccentricity ex only is read on the interaction diagram of the column about one axis, for the eccentricity of the load in that direction. The same is done for the other axis. The values come from a column design chart, a program or a hand calculation with the strain compatibility, and they must be the nominal values, without the reduction factor.

What are the limits of the calculator?

The calculator applies only the reciprocal load equation to the capacities that you enter. It does not check the slenderness of the column, the moment magnification, the shear, the reinforcement limits or the detailing. Other methods, as the contour method of the PCA, give a closer result for the columns with a small axial load. The design must follow the standard.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.