Reinforced concrete column axial capacity calculator: maximum axial load of a short concrete column

Enter the column size, the steel area, the material strengths and the type of ties to get the steel ratio, the nominal axial strength, the maximum nominal strength and the design axial strength.

Updated on
Your inputs
in

Value out of range

in

Value out of range

in²

Value out of range

ksi

Value out of range

ksi

Value out of range

Results

Design axial strength φPn,max

948.0 kips

Gross area of the column
324 in²
Steel ratio ρ
2.47 %
The steel ratio is within the limits of 1% to 8%
Nominal axial strength Po
1,823.0 kips
Maximum nominal strength Pn,max
1,458.4 kips

The reinforced concrete column axial capacity calculator gives the nominal axial strength Po, the maximum nominal strength and the design axial strength of a short concrete column from its size, steel area, material strengths and type of ties, with the steel ratio check of ACI 318.

How the calculation works

  • Enter the width and the depth of the column and the total area of the longitudinal bars.
  • Enter the concrete strength f′c and the steel yield strength fy.
  • Choose the transverse reinforcement: ties (φ = 0.65) or a spiral (φ = 0.75).
  • The calculator finds Po = 0.85 f′c (Ag − Ast) + fy Ast, the maximum strength 0.80 Po for ties or 0.85 Po for a spiral, and the design strength φPn,max, with the steel ratio check.

Example

A tied column of 18 in × 18 in (Ag = 324 in²) has 8.0 in² of steel (eight No. 9 bars), f′c = 5 ksi and fy = 60 ksi. The steel ratio is 8 / 324 = 2.47%. Then Po = 0.85 × 5 × (324 − 8) + 60 × 8 = 1,823 kips. The maximum nominal strength is 0.80 × 1,823 = 1,458.4 kips, and the design strength is 0.65 × 1,458.4 = 948.0 kips.

Why it matters

The calculator helps structural engineers, builders and students to estimate the load that a concrete column can carry, to check the size of a column in a first design and to compare ties and spirals or different steel amounts. It gives the upper limit used as the starting point of the interaction diagram.

Good to know

Use the actual steel area of the bars chosen, and check the minimum and maximum ratios. Remember that the pure axial load is an upper limit: real columns also carry moments, which reduce the axial capacity. Check the slenderness, the ties, the splices and the punching shear at the slab. A licensed engineer must verify the design.

The punching shear calculator checks the slab at the column, the steel column capacity calculator covers steel columns, the Euler buckling calculator covers slender columns and the concrete volume calculator gives the quantity of concrete.

Frequently asked questions

How is the axial strength of a column found?

For a short column under a pure axial load, the strength is the sum of the contribution of the concrete and of the steel: Po = 0.85 f′c (Ag − Ast) + fy Ast. The factor 0.85 accounts for the difference between the strength of the concrete in the column and in the cylinder test. Because no real column is perfectly centered, the code limits the usable strength to 80% of Po for tied columns and 85% for spiral columns.

What is the strength reduction factor?

ACI 318 uses φ = 0.65 for compression-controlled sections with ties and 0.75 with spirals, because spirals confine the concrete better and give a more ductile failure with warning. The columns with combined axial load and bending have an interaction diagram, and this calculator gives only the pure axial point, which is the upper limit.

What are the steel limits?

ACI 318 requires a longitudinal steel ratio of at least 1% of the gross area, to resist the unexpected bending and to limit the creep and shrinkage effects, and at most 8%, which in practice is about 4% to leave room for the concrete. Columns also need a minimum of four bars in a rectangular section, ties of a given size and spacing, and a cover. The calculator shows the ratio and checks the limits.

What are the limits of the calculator?

It is for short columns where the slenderness effects can be neglected, loaded concentrically. Columns with a significant moment, slender columns, and columns of high-strength materials need the interaction diagram and the second-order analysis. The detailing, the splices and the seismic requirements are separate, and a licensed engineer must design a real column.