Skip to content
Omnikalc

Cable stay force, area and Ernst modulus calculator

Enter the geometry of a stay, the vertical load it carries and the strand properties to get the stay length, force, steel area, horizontal force in the deck, Ernst modulus ratio and elongation.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

kips

Value out of range

ksi

Value out of range

ksi

Value out of range

pcf

Value out of range

Results

Stay force

283.0 kips

Length of the stay
235.8 ft
Stay inclination sin α
0.530
The stay is at least 25 degrees above the deck
Steel area required
2.33 in²
Horizontal force in the deck
240.0 kips
Ernst modulus ratio
0.9994
Elongation of the stay
11.86 in

The cable stay calculator gives the force of a stay of a cable-stayed bridge from the vertical load and the inclination, the strand area, the horizontal push on the deck, the Ernst equivalent modulus and the elongation.

How the calculation works

  • Enter the horizontal distance from the tower to the deck anchor, the height of the anchor on the tower and the vertical load the stay carries.
  • Enter the strand strength, the modulus and the unit weight of the steel.
  • The calculator gives the stay length, the force, the steel area, the horizontal force in the deck, the Ernst modulus and the elongation.

Example

A stay anchored on the deck 200 ft from the tower and 125 ft below its anchor point carries a vertical load of 150 kips. The stay is √(200² + 125²) = 235.8 ft long, with sin α = 125 / 235.8 = 0.530, about 32 degrees from the deck. The force is 150 / 0.530 = 283.0 kips. With an allowable stress of 0.45 × 270 = 121.5 ksi, the strand area is 2.33 in². The stay pushes on the deck with a horizontal force of 150 × 200 / 125 = 240 kips. The sag of the stay reduces its stiffness slightly, by the Ernst ratio of 0.9994, and the stay lengthens by 11.9 in under this force.

Why it matters

The calculator helps bridge designers, students and engineers of masts, cable roofs and footbridges to see how the slope of a stay changes its force and the compression of the deck. A flat stay is inefficient: it carries the same vertical load with a larger force and pushes the deck harder.

Good to know

Keep the stays steeper than about 25 degrees from the horizontal, as flatter stays need much more steel and compress the deck. Take the vertical load as the tributary dead load plus the live load of the panel. The Ernst correction matters for long stays at a low stress, over about 300 ft. For a harp arrangement, the stays are parallel, and for a fan arrangement, they meet at the top of the tower, so each stay has its own slope.

The cable sag calculator gives the sag of a hanging cable, the pedestrian bridge calculator checks the frequency of a footbridge, the post-tensioning tendon calculator gives the elongation of a tendon and the wire rope calculator gives the breaking force of a rope.

Frequently asked questions

How is the force in a stay found?

A stay carries only tension along its length. Its vertical component must equal the load of the deck panel that it supports, so the force is T = Q / sin α, where α is the angle between the stay and the horizontal. The horizontal component, Q / tan α, is an axial force that compresses the deck, and it adds up along the span. The calculator gives both for one stay.

What is the Ernst modulus?

A stay sags under its own weight, so a change in the tension changes its length by more than the strain of the steel alone. Ernst replaced the sagging stay by a straight bar with an equivalent modulus, E_eq = E / (1 + (γ L_h)² E / (12 σ³)), where γ is the unit weight of the steel, L_h the horizontal length and σ the stress. The ratio is near 1 for a taut or short stay and falls for a long stay at a low stress.

Why use 0.45 of the ultimate strength?

Codes limit the stress of a stay under the permanent load plus the live load to about 45 percent of the guaranteed ultimate tensile strength, to protect against fatigue at the anchorages and to keep a good margin. The calculator uses this value to size the area from the force. You can scale the force to change the ratio, if your code gives another limit.

What does the calculator leave out?

The calculator takes one stay with a given vertical load. It leaves out the stages of construction, the load share between the stays, the live load patterns, the flexure of the tower and the deck, the wind and the vibration of the stay, and the fatigue. Use it to estimate the size of a stay and the effect of its slope, and rely on a full analysis for the design.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.