Skip to content
Omnikalc

Post-tensioning tendon elongation and jacking gauge calculator

Enter the strands, the jacking force, the length, the friction and the jack piston area to get the expected elongation, the force at the far end and the gauge pressure.

Updated on
Your inputs

Value out of range

ksi

Value out of range

%

Value out of range

ksi

Value out of range

ft

Value out of range

Value out of range

per ft

Value out of range

rad

Value out of range

in²

Value out of range

Results

Expected elongation

7.08 in

Steel area of the tendon
2.604 in²
Jacking force
562.5 kips
Force at the far end
531.8 kips
Gauge pressure of the jack
5,625 psi
Friction loss along the tendon
5.4 %

The post-tensioning tendon elongation calculator gives the jacking force, the friction loss, the force at the far end, the expected elongation and the gauge pressure of the jack for a strand tendon.

How the calculation works

  • Enter the number and the type of strands, their ultimate strength and modulus.
  • Enter the jacking force as a share of the ultimate, the length of the tendon and the friction coefficients and the angle change.
  • Enter the piston area of the jack to get the elongation, the force at the far end and the gauge pressure.

Example

A tendon of 12 strands of 0.6 in has a steel area of 2.604 in². Jacked to 80 % of 270 ksi, the force is 562.5 kips. Over 80 ft, with μ = 0.20, K = 0.0002 per ft and an angle change of 0.20 rad, the friction loss reaches 5.4 % and the force at the far end is 531.8 kips. The average force gives an elongation of 7.08 in. With a jack piston of 100 in², the gauge reads 5,625 psi.

Why it matters

The calculator helps post-tensioning crews, site engineers, inspectors and students to prepare the stressing record, to check the measured elongations against the calculated ones and to see the effect of the friction and the length of the tendon.

Good to know

Calculate the elongation with the friction coefficients of the design and the actual modulus of the strand from the mill certificate. Mark the strands before stressing, take the readings at stages, and correct for the initial force of the seating. Compare the elongation and the pressure at each tendon, and stop and call the engineer if the difference is more than the tolerance.

The tendon friction loss calculator gives the loss along a tendon, the prestress loss calculator gives the long-term losses, the prestressed beam stress calculator checks the stresses of a beam and the anchorage zone calculator gives the bursting force behind an anchor.

Frequently asked questions

Why is the elongation calculated?

When a post-tensioning tendon is stressed, the crew measures the elongation of the tendon and the pressure of the jack. The measured elongation is compared with the calculated one, and the two must agree within a tolerance, usually 7 %. A difference shows a problem such as a blocked duct, a strand that slips, a wrong jack calibration or a higher friction than assumed. The calculated value is therefore a field control.

What is the formula?

The elongation is Δ = P_avg L / (A E), where P_avg is the average force along the tendon, L its length, A the steel area and E the modulus. The force decreases from the jack to the far end by friction, P = Pj e^(−(μ α + K L)), with μ the curvature friction coefficient, α the total angle change in radians, K the wobble coefficient and L the length. The average force over the length is Pj (1 − e^(−x)) / x, with x = μ α + K L.

How is the gauge pressure found?

The jacking force equals the pressure on the piston times the piston area, so the gauge pressure is the jacking force divided by the piston area. The jack and the gauge are calibrated together, and the calibration chart of the jack gives the correct reading, including the friction of the seals. The calculator gives the theoretical pressure to compare with the chart and to check the range of the gauge.

What does the calculator leave out?

The calculator leaves out the seating loss at the anchor, the initial slack and the elongation of the tail of the strand outside the anchor, the elastic shortening of the concrete and the effect of tendons stressed in sequence. It also uses one value of the friction coefficients for the whole tendon. Take the coefficients from the tendon supplier and from the design drawings, and let the engineer of record fix the tolerance.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.