The post-tensioning tendon elongation calculator gives the jacking force, the friction loss, the force at the far end, the expected elongation and the gauge pressure of the jack for a strand tendon.
How the calculation works
- Enter the number and the type of strands, their ultimate strength and modulus.
- Enter the jacking force as a share of the ultimate, the length of the tendon and the friction coefficients and the angle change.
- Enter the piston area of the jack to get the elongation, the force at the far end and the gauge pressure.
Example
A tendon of 12 strands of 0.6 in has a steel area of 2.604 in². Jacked to 80 % of 270 ksi, the force is 562.5 kips. Over 80 ft, with μ = 0.20, K = 0.0002 per ft and an angle change of 0.20 rad, the friction loss reaches 5.4 % and the force at the far end is 531.8 kips. The average force gives an elongation of 7.08 in. With a jack piston of 100 in², the gauge reads 5,625 psi.
Why it matters
The calculator helps post-tensioning crews, site engineers, inspectors and students to prepare the stressing record, to check the measured elongations against the calculated ones and to see the effect of the friction and the length of the tendon.
Good to know
Calculate the elongation with the friction coefficients of the design and the actual modulus of the strand from the mill certificate. Mark the strands before stressing, take the readings at stages, and correct for the initial force of the seating. Compare the elongation and the pressure at each tendon, and stop and call the engineer if the difference is more than the tolerance.
Related tools
The tendon friction loss calculator gives the loss along a tendon, the prestress loss calculator gives the long-term losses, the prestressed beam stress calculator checks the stresses of a beam and the anchorage zone calculator gives the bursting force behind an anchor.