The pedestrian bridge frequency calculator gives the first vertical natural frequency of a simply supported bridge, its ratio to the frequency limit (3 Hz in the AASHTO guide), the moment of inertia needed for the limit and the dead load deflection.
How the calculation works
- Enter the span, the modulus of elasticity, the moment of inertia and the weight per foot of the bridge.
- Enter the frequency limit, 3 Hz for the vertical vibration in the AASHTO guide.
- The calculator gives the first vertical frequency, the ratio to the limit, the inertia needed and the dead load deflection.
Example
A simply supported bridge of 60 ft with 29,000 ksi steel, an inertia of 5,400 in⁴ and a weight of 600 lb/ft has a mass of 600 / 12 / 386.4 = 0.1294 lb·s²/in². The first frequency is f = π / (2 L²) × √(E I / m) = 3.33 Hz, a ratio of 1.11 to the limit of 3.0 Hz. The inertia needed for exactly 3.0 Hz is 4,374 in⁴. The deflection under the dead load is 1.12 in.
Why it matters
The calculator helps bridge engineers, architects, designers of footbridges and students to check the vertical frequency of a pedestrian bridge at the start of a design, to choose the depth of the girders and to decide if a vibration analysis is needed.
Good to know
Use the weight of the deck, the finishes, the railings and the services, since the mass lowers the frequency, and the composite section stiffness with the modular ratio for a concrete deck. Check the frequency again with the final weights. For a long span, a light deck or a bridge near a gym, a stadium or a railway station, ask for a dynamic analysis even if the frequency is above 3 Hz.
Related tools
The floor walking vibration calculator checks the peak acceleration of a floor, the tuned mass damper calculator sizes a damper, the beam deflection calculator gives the deflection of a beam and the steel beam lateral-torsional buckling calculator checks the flexural strength.