Skip to content
Omnikalc

Column brace strength and stiffness requirement calculator

Enter the column axial force, the brace spacing and the brace member to get the required brace strength and stiffness of AISC 360 appendix 6, the stiffness provided and the force in the brace.

Updated on
Your inputs
kips

Value out of range

ft

Value out of range

in²

Value out of range

°

Value out of range

ft

Value out of range

Results

Required brace stiffness

31.7 kip/in

Required brace strength
4.00 kips
Stiffness provided by the brace
120.8 kip/in
Provided over required
3.81
The brace is stiff enough
Axial force in the brace member
5.66 kips

The column brace calculator gives the required strength and stiffness of a nodal or relative brace by AISC 360 appendix 6, the stiffness provided by a diagonal brace and the force in it.

How the calculation works

  • Enter the required axial strength of the column and the distance between braces.
  • Choose nodal or relative bracing and the design method, then the area, angle and length of the brace.
  • The calculator gives the required brace strength and stiffness, the stiffness provided and the force in the brace member.

Example

A column with a required strength of 400 kips is braced at 14 ft by a nodal brace. The required strength is 0.01 × 400 = 4.0 kips and the required stiffness, with φ = 0.75, is (1 / 0.75) × 10 × 400 / (14 × 12) = 31.7 kip/in. A brace of 2 in² at 45° to the perpendicular and 20 ft long gives 2 × 29,000 × cos²45° / (20 × 12) = 120.8 kip/in, 3.8 times the requirement, with an axial force of 5.7 kips.

Why it matters

The calculator helps structural engineers, detailers and students to size the bracing of columns, studs and compression chords, and to check that a strut or a diagonal is stiff enough, not only strong enough.

Good to know

Take the required axial strength of the column at the brace as the load combination that controls, not the capacity. Compare the stiffness of the brace with the requirement including the connection and the supporting member, since a long thin rod brace or a flexible support can fail the check. The distance between braces is the unbraced length used in the column strength. The requirements assume the column is braced for the buckling load of the length between braces, and a larger brace stiffness is needed if the column is stressed above that. For a column with a bow, increase the brace strength.

The steel column capacity calculator gives the axial strength, the Euler buckling calculator gives the buckling load, the effective length calculator gives the K factor and the B1 moment amplification calculator handles a column with bending.

Frequently asked questions

Why does a brace need a minimum stiffness?

A brace that stops a column from buckling between its points acts like a spring. If the spring is soft, the column moves at the brace and the brace does not work. A minimum stiffness is needed for the brace to hold the point still enough, and a minimum strength, about 1 % of the axial load, to resist the force that grows from the initial out-of-straightness of the column.

What is the difference between nodal and relative bracing?

A nodal brace restrains one point of the column against movement, such as a strut at midheight to a fixed point. A relative brace controls the movement of one point of the column compared with an adjacent point, for example a diagonal in a braced frame. The relative brace needs a strength of 0.4 % and a stiffness five times smaller than the nodal brace.

What is the stiffness of the diagonal?

A diagonal brace at an angle θ to the direction of the force it resists has a stiffness in that direction of A E cos²θ / L. The calculator also takes the force in the brace as the required strength divided by cos θ. The stiffness of the connections and the supports adds flexibility, so the real stiffness is lower.

What does the calculator leave out?

The calculator leaves out the beam bracing, the brace of a column with an initial bow larger than L/1000, several braces along the column, the brace connections and the flexibility of the supporting structure. The formulas are for a column that is braced at the points of the spacing. Use the full appendix 6 and the design requirements of your project.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.