The column effective length factor calculator gives the stiffness ratios G at the two joints, the effective length factor K of the alignment chart for a braced or unbraced frame, the effective length KL and the slenderness KL/r.
How the calculation works
- Enter the moment of inertia, the height and the radius of gyration of the column.
- Enter the beams that frame into the top joint and into the bottom joint, or choose a fixed or pinned base, and choose braced or unbraced.
- The calculator finds the stiffness ratios G, the effective length factor K, the effective length and the slenderness.
Example
A W14×90 column (I = 999 in⁴, r = 6.14 in) 14 ft high is framed at the top to two beams of 1,350 in⁴ and 30 ft and at the bottom to two beams of 843 in⁴ and 30 ft. The stiffness ratios are G = 1.59 at the top and 2.54 at the bottom. In an unbraced frame K = 1.62, so KL = 1.62 × 14 = 22.7 ft and KL/r = 44.3. In a braced frame the same column has K = 0.86 only.
Why it matters
The calculator helps structural engineers, steel designers and students to get the K factor of a frame column without reading the nomograph, to compare a braced with an unbraced frame, and to see how the stiffness of the beams or the fixity of the base changes the buckling length.
Good to know
Use the stiffness of the beams with the correct end condition: for a beam far end pinned, multiply its stiffness by 1.5 in a braced frame, and by 0.5 in an unbraced one. Use the gross moment of inertia for an elastic check and keep K at least 1.0 for an unbraced frame. For a pinned base the AISC commentary allows a G of 10, and for a base with a real footing a G between 1 and 5 is common, so a G of 1 is only for a base really fixed.
Related tools
The steel column capacity calculator gives the AISC strength from KL/r, the Euler buckling calculator gives the elastic critical load, the base plate size calculator sizes the plate under the column and the wood column capacity calculator does the same check for a post.