Skip to content
Omnikalc

Curb opening inlet capacity calculator: flow into a curb inlet from the ponded depth, with clogging

Enter the length and height of the curb opening, the depth of water, the clogging allowance and the design flow to get the weir flow, the orifice flow, the capacity with clogging and the ratio to the design flow.

Updated on
Your inputs
ft

Value out of range

in

Value out of range

in

Value out of range

%

Value out of range

cfs

Value out of range

Results

Capacity with clogging

2.62 cfs

Weir flow of the opening
2.91 cfs
Orifice flow of the opening
5.21 cfs
Design flow over the capacity
0.76
The inlet can take the design flow

The curb opening inlet capacity calculator gives the flow into a curb inlet in a sag from the length and the height of the opening and the depth of water, as a weir and as an orifice, with a clogging allowance and the ratio to the design flow.

How the calculation works

  • Enter the length and the height of the curb opening of the inlet.
  • Enter the depth of water at the inlet, measured at the curb face, which is the ponding in a sag or at the low point.
  • Enter a clogging allowance for debris and the design flow that comes to the inlet.
  • The calculator finds the flow as a weir and as an orifice, the capacity with clogging and the ratio of the design flow to this capacity.

Example

A curb opening of 5 ft and 6 in high has 4.8 in of water at the inlet in a sag. As a weir it passes 2.3 × 5 × 0.4^1.5 = 2.91 cfs, and as an orifice 0.67 × 0.5 × 5 × √(64.4 × (0.4 − 0.25)) = 5.21 cfs. The depth is less than the height of the opening, so the weir governs. With 10% clogging the capacity is 2.91 × 0.9 = 2.62 cfs, and a design flow of 2 cfs is 0.76 of it.

Why it matters

The calculator helps civil engineers, drainage designers, municipal staff and students to check that a curb inlet at a low point can take the flow of the storm without too much ponding on the street, to compare lengths of opening and to see the effect of clogging. It complements the grate inlet calculator for the other common type of inlet.

Good to know

Use the depth of ponding that the street can tolerate, usually limited by the crown of the road or the top of the curb, and design the inlet at low points with a clogging allowance. Add a second inlet or a longer opening if the ratio is above 1, and make sure there is an overflow path for storms greater than the design storm.

The grate inlet capacity calculator covers the inlets with a grate, the rational method calculator gives the design flow, the Manning equation calculator sizes the gutter and the pipes, and the culvert pipe size calculator sizes a culvert that receives the flow.

Frequently asked questions

What is a curb opening inlet?

A curb opening inlet is a storm drain inlet with an opening in the face of the curb, through which the water of the gutter enters the drain. It does not clog easily with leaves and trash as a grate does, and it is safe for bicycles, so it is often preferred on streets with a lot of debris. It can be placed on a slope, with the interception depending on the length of the opening, or in a sag, at the low point.

How is the capacity in a sag found?

In a sag the inlet takes the water that ponds against the curb. When the depth is smaller than the height of the opening, it works as a weir, with Q = 2.3 L d^1.5 in feet and cfs. When the depth is more than about 1.4 times the height, it works as an orifice, with Q = 0.67 h L √(2 g (d − h/2)). Between these two, the smaller of the two flows is a safe estimate.

Why is a clogging allowance used?

Leaves, plastic and sediment reduce the real opening, and during a storm the inlet can capture less than the clean-condition flow. A reduction of 10% is common for curb openings, and 25 to 50% for grates. The allowance is applied to the capacity, so that the design flow is compared to a lower, more realistic value, and the extra flow bypasses to the next inlet or ponds on the street.

What are the limits of the calculator?

The calculator applies to an inlet in a sag with no depression of the gutter. A depressed opening, an inlet on a continuous grade, a combination inlet with a grate, and the flow that is deflected by the curb all have other equations in HEC-22. The allowable ponding on the street must also be checked. The result is an estimate for the design of a drainage by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.