The curb opening inlet capacity calculator gives the flow into a curb inlet in a sag from the length and the height of the opening and the depth of water, as a weir and as an orifice, with a clogging allowance and the ratio to the design flow.
How the calculation works
- Enter the length and the height of the curb opening of the inlet.
- Enter the depth of water at the inlet, measured at the curb face, which is the ponding in a sag or at the low point.
- Enter a clogging allowance for debris and the design flow that comes to the inlet.
- The calculator finds the flow as a weir and as an orifice, the capacity with clogging and the ratio of the design flow to this capacity.
Example
A curb opening of 5 ft and 6 in high has 4.8 in of water at the inlet in a sag. As a weir it passes 2.3 × 5 × 0.4^1.5 = 2.91 cfs, and as an orifice 0.67 × 0.5 × 5 × √(64.4 × (0.4 − 0.25)) = 5.21 cfs. The depth is less than the height of the opening, so the weir governs. With 10% clogging the capacity is 2.91 × 0.9 = 2.62 cfs, and a design flow of 2 cfs is 0.76 of it.
Why it matters
The calculator helps civil engineers, drainage designers, municipal staff and students to check that a curb inlet at a low point can take the flow of the storm without too much ponding on the street, to compare lengths of opening and to see the effect of clogging. It complements the grate inlet calculator for the other common type of inlet.
Good to know
Use the depth of ponding that the street can tolerate, usually limited by the crown of the road or the top of the curb, and design the inlet at low points with a clogging allowance. Add a second inlet or a longer opening if the ratio is above 1, and make sure there is an overflow path for storms greater than the design storm.
Related tools
The grate inlet capacity calculator covers the inlets with a grate, the rational method calculator gives the design flow, the Manning equation calculator sizes the gutter and the pipes, and the culvert pipe size calculator sizes a culvert that receives the flow.