The design response spectrum calculator gives the spectral acceleration Sa at the period of a structure from the design values SDS and SD1 and the long-period transition TL, as in ASCE 7-22 section 11.4.6, with the periods T0 and TS of the plateau and the seismic response coefficient Cs.
How the calculation works
- Enter the design spectral accelerations SDS and SD1 of the site, which come from the seismic hazard map and the site class, and the long-period transition period TL.
- Enter the period T of the structure, the response modification coefficient R and the importance factor Ie of the building.
- The calculator gives the periods T0 and TS of the plateau, the spectral acceleration Sa(T) of the design spectrum of ASCE 7 section 11.4.6 and the seismic response coefficient Cs.
Example
A site has SDS = 1.0 g, SD1 = 0.6 g and TL = 8 s. The plateau ends at TS = SD1 / SDS = 0.60 s and starts at T0 = 0.2 TS = 0.12 s. A building with a period T = 0.8 s is on the descending branch, where Sa = SD1 / T = 0.6 / 0.8 = 0.75 g. For R = 8 and Ie = 1, the response coefficient is Cs = 0.75 / 8 = 0.0937, which is larger than the minimum 0.044 SDS Ie = 0.044. The ratio Sa / SDS is 0.75, so the building is on the sloping part of the spectrum, with a demand lower than the peak.
Why it matters
The calculator helps structural engineers, students and plan reviewers to build the design spectrum quickly, to see on which branch a building falls, to compare the demand of two periods, for example a braced and a moment frame, and to check a hand calculation of the base shear before the modeling in an analysis program.
Good to know
Take SDS and SD1 from the official hazard tool for the exact address, the risk category and the site class, and update them when the code edition changes. Compare the period of the model with the approximate period Ta and with the upper limit Cu Ta. Remember that a longer period lowers the force on the sloping branch, but raises the drift and the displacement. For long structures, check the period against TL, and for the design drift use the amplified displacement of the structure, not the force. Keep the value of R and Ie that matches the structural system of the table, the risk category of the building and the detailing used, and recompute the spectrum when the site class or the hazard values are updated by a geotechnical report or by a new code edition.
Related tools
The seismic base shear calculator applies Cs to the weight of the building, the story drift calculator checks the displacement under the lateral forces, the diaphragm shear calculator distributes the forces in the floors and the pushover calculator idealizes the capacity curve of the structure.