The diaphragm calculator gives the support shear, the maximum unit shear, the chord force and the demand to capacity ratio of a flexible roof or floor diaphragm loaded by wind or earthquake, from the load, the span and the depth.
How the calculation works
- Enter the uniform lateral load (wind or seismic) on the diaphragm, its span between the shear walls and its depth.
- Enter the allowable unit shear of the diaphragm, from the sheathing and the nailing.
- The calculator finds the shear at the supports, the maximum unit shear, the chord force at the edges and the demand to capacity ratio.
Example
A roof diaphragm is 60 ft long between the shear walls and 30 ft deep, with a lateral load of 300 plf. The shear at each support is 300 × 60 / 2 = 9,000 lb. The unit shear is 9,000 / 30 = 300 plf, which is 0.88 of the allowable value of 340 plf. The chord force is 300 × 60² / (8 × 30) = 4,500 lb.
Why it matters
The calculator helps structural engineers, designers, builders and students to check a roof or floor diaphragm in a first design, to see the effect of the span and the depth, and to size the chords, the nailing and the connections to the shear walls.
Good to know
Use the load of the controlling case from the code, check both directions, and add the collectors for the loads that come from the walls. Verify the nailing pattern, the splices of the chords and the connection of the diaphragm to the walls, where the shear is highest. Where the shear is much lower near the middle of the span, a lighter nailing pattern can be used, which saves labor and cost on a large roof.
Related tools
The shear wall demand and holddown calculator checks the walls, the wind load calculator gives the load, the seismic base shear calculator gives the earthquake force and the load combinations calculator combines the loads.