The drilled shaft capacity calculator gives the axial capacity of a bored pile in clay with the alpha method of the FHWA: the side resistance, the end bearing, the ultimate and the allowable capacity, from the diameter, the length and the undrained shear strength.
How the calculation works
- Enter the diameter and the length of the drilled shaft.
- Enter the undrained shear strength of the clay along the shaft and at the base, from the soil report.
- Enter the safety factor and the service load of the shaft.
- The calculator finds the side resistance (alpha method, α = 0.55, neglecting the top 5 ft and the bottom diameter), the end bearing (Nc = 9), the ultimate and allowable capacity and the ratio to the load.
Example
A shaft of 3 ft of diameter and 40 ft of length is in a clay with 1.5 ksf along the shaft and 3.0 ksf at the base. The side resistance is 0.55 × 1.5 × π × 3 × (40 − 5 − 3) = 248.8 kips, and the end bearing is 9 × 3.0 × π × 3² / 4 = 190.9 kips. The ultimate capacity is 439.7 kips, which is 175.9 kips with a safety factor of 2.5. A service load of 150 kips is 0.85 of it.
Why it matters
The calculator helps geotechnical and structural engineers, foundation contractors and students to size a drilled shaft in a first design, to compare the diameter and the length and to see the share of the side resistance and of the end bearing. It reproduces the classic hand calculation for a shaft in clay.
Good to know
Use values of su from laboratory tests or in situ tests at the depth of each layer, and neglect the top of the shaft where the soil is disturbed. Make the safety factor at least 2.5, or use the resistance factors of the LRFD method. Check the settlement and the lateral loads, and verify the shaft on site with load tests.
Related tools
The pile capacity calculator covers driven piles, the bearing capacity calculator covers shallow foundations, the pile group efficiency calculator covers groups of piles and the soil unit weight calculator converts the soil density.