Depth of influence

25.9 ft

Energy of one drop
900 ton-ft
Applied energy per area
44.4 ton-ft/ft²
Usual range for the improvement of granular soils

The dynamic compaction calculator gives the depth of influence, the energy of one drop and the energy applied per unit of area of a heavy tamping soil improvement, from the weight of the pounder, the drop height, the soil factor, the drops per print, the passes and the spacing of the grid.

How the calculation works

  • Enter the weight of the pounder and the drop height, and choose the soil factor n.
  • Enter the drops per print, the number of passes and the spacing of the grid of the prints.
  • The calculator finds the depth of influence, the energy of one drop and the energy applied per unit of area.

Example

A pounder of 15 tons is dropped from 60 ft on a sand with n = 0.50. The depth of influence is 0.50 × √(15 × 0.9072 × 60 × 0.3048) / 0.3048 = 25.9 ft. The energy of one drop is 15 × 60 = 900 ton-ft. With 8 drops per print, 2 passes and a grid of 18 ft, the applied energy is 900 × 8 × 2 / 18² = 44.4 ton-ft/ft², inside the usual range.

Why it matters

The calculator helps geotechnical engineers, ground improvement contractors, developers and students to choose a pounder and a drop height for a target depth, to estimate the energy of a program and to compare dynamic compaction with other ways to improve a loose fill.

Good to know

Run a trial area with the pounder and the grid of the design, and measure the crater depth, the settlement, the vibration and the improvement with the in-situ tests. Spread a working platform of granular fill, apply the energy in passes, and finish with a low-energy ironing pass. Keep a safe distance from the buildings and the services, and monitor the vibrations at the nearest structures.

The soil compaction calculator checks the density of a fill, the bearing capacity calculator gives the capacity of the improved soil, the elastic settlement of footing calculator checks the settlement and the wick drain consolidation time calculator handles the clays.

Frequently asked questions

What is dynamic compaction?

Dynamic compaction, or heavy tamping, is a ground improvement method in which a heavy weight, the pounder, is dropped from a crane on a grid of points. The impacts densify the loose granular soils, the fills and the old landfills to a great depth, and reduce the settlement. The method was developed by Menard in France, and it is economical for large areas of loose soil.

How is the depth of influence estimated?

The depth of influence is given by the formula of Menard, D = n × √(W × H), where W is the weight of the pounder in metric tons, H is the drop height in meters and n is a factor between 0.3 and 0.8 that depends on the soil. A factor of 0.5 is usual for sand and gravel. The real depth is checked with the field tests, such as the CPT or the pressuremeter, before and after the work.

What is the applied energy?

The applied energy is the energy of the drops divided by the area of the grid, found from the energy per drop, the drops per print, the number of passes and the spacing of the prints. Values of 15 to 60 ton-ft/ft² (400 to 1,750 kJ/m²) are common for granular soils, and the energy is applied in several passes with a rest between them to let the pore pressures dissipate in a soil with fines.

What are the limits of the calculator?

The calculator gives a first estimate of the depth and of the energy. It does not include the ground vibration and the effect on nearby buildings, the water table, the thickness of the working platform, the crater depth, the ironing pass, the saturated clays that need a different method or the test program. A geotechnical engineer must design the work and the control tests.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.