The wick drain calculator gives the zone of influence, the spacing ratio, the drain factor, the time to reach a target degree of consolidation and the degree reached after a given time for prefabricated vertical drains in soft clay, by the Barron radial consolidation theory.
How the calculation works
- Enter the spacing of the vertical drains, choose the pattern and enter the equivalent diameter of the drain.
- Enter the horizontal coefficient of consolidation ch of the clay, the target degree of consolidation and a time elapsed to check.
- The calculator finds the diameter of the zone of influence, the spacing ratio, the drain factor, the time to reach the target degree and the degree reached at the time elapsed, by the Barron theory of radial consolidation.
Example
Wick drains are installed in a triangular pattern at 5 ft, with an equivalent diameter of 0.22 ft and ch = 0.8 ft²/day. The zone of influence is de = 1.05 × 5 = 5.25 ft, so n = 5.25 / 0.22 = 23.9 and F(n) = ln 23.9 − 0.75 = 2.422. The time for 90 % is 5.25² × 2.422 / (8 × 0.8) × ln(1 / 0.1) = 24.0 days. After 14 days, the degree is 1 − exp(−8 × 0.8 × 14 / (5.25² × 2.422)) = 73.9 %.
Why it matters
The calculator helps geotechnical engineers, ground improvement contractors, designers and students to choose the spacing of vertical drains under an embankment or a preload in a first design, and to see how much the spacing and the coefficient ch change the time.
Good to know
Obtain ch from dissipation tests or from a lab test with horizontal drainage, and use a conservative value. Add a smear effect in the final design, install settlement plates and piezometers, and keep the preload until the monitoring shows that the target is reached.
Related tools
The consolidation time calculator gives the vertical consolidation of a clay layer, the consolidation settlement calculator gives the total settlement, the Darcy’s law calculator gives the flow in the soil and the soil compaction calculator checks the fill.