Enter the spacing, the pattern, the drain diameter, the horizontal coefficient of consolidation, the target degree and the time elapsed to get the zone of influence, the spacing ratio, the drain factor, the time needed and the degree reached.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft²/day

Value out of range

%

Value out of range

days

Value out of range

Results

Time to reach the target degree

24.0 days

Diameter of the zone of influence
5.25 ft
Spacing ratio n = de / dw
23.9
Drain factor F(n)
2.422
Degree of consolidation at the time elapsed
73.9 %

The wick drain calculator gives the zone of influence, the spacing ratio, the drain factor, the time to reach a target degree of consolidation and the degree reached after a given time for prefabricated vertical drains in soft clay, by the Barron radial consolidation theory.

How the calculation works

  • Enter the spacing of the vertical drains, choose the pattern and enter the equivalent diameter of the drain.
  • Enter the horizontal coefficient of consolidation ch of the clay, the target degree of consolidation and a time elapsed to check.
  • The calculator finds the diameter of the zone of influence, the spacing ratio, the drain factor, the time to reach the target degree and the degree reached at the time elapsed, by the Barron theory of radial consolidation.

Example

Wick drains are installed in a triangular pattern at 5 ft, with an equivalent diameter of 0.22 ft and ch = 0.8 ft²/day. The zone of influence is de = 1.05 × 5 = 5.25 ft, so n = 5.25 / 0.22 = 23.9 and F(n) = ln 23.9 − 0.75 = 2.422. The time for 90 % is 5.25² × 2.422 / (8 × 0.8) × ln(1 / 0.1) = 24.0 days. After 14 days, the degree is 1 − exp(−8 × 0.8 × 14 / (5.25² × 2.422)) = 73.9 %.

Why it matters

The calculator helps geotechnical engineers, ground improvement contractors, designers and students to choose the spacing of vertical drains under an embankment or a preload in a first design, and to see how much the spacing and the coefficient ch change the time.

Good to know

Obtain ch from dissipation tests or from a lab test with horizontal drainage, and use a conservative value. Add a smear effect in the final design, install settlement plates and piezometers, and keep the preload until the monitoring shows that the target is reached.

The consolidation time calculator gives the vertical consolidation of a clay layer, the consolidation settlement calculator gives the total settlement, the Darcy’s law calculator gives the flow in the soil and the soil compaction calculator checks the fill.

Frequently asked questions

What are wick drains?

Wick drains, or prefabricated vertical drains, are strips of plastic core wrapped in a geotextile, about 4 in (100 mm) wide and 0.1 in (3 mm) thick, which are pushed into soft clay under an embankment or a preload. They shorten the drainage path of the pore water from the thickness of the layer to half the spacing between the drains, so the clay consolidates in weeks and not in years.

What is the Barron theory?

Barron’s theory describes the consolidation by a radial flow to a vertical drain in a cylinder of soil. For an ideal drain without smear, the average degree of radial consolidation is Uh = 1 − exp(−8 Th / F(n)), where Th = ch t / de² is the time factor and F(n) = ln(n) − 0.75 is the drain factor, n being the ratio of the diameter of the zone of influence to the diameter of the drain. The time is then found from the target degree.

How is the equivalent diameter of a wick drain found?

A strip drain is replaced by a circular drain of equivalent perimeter, dw = 2 (a + b) / π, where a and b are the width and the thickness of the strip. For a 4 in by 0.1 in strip, the equivalent diameter is about 2.6 in (0.22 ft or 66 mm). The zone of influence of a drain is a circle of equivalent area, with de = 1.05 s for a triangular pattern and 1.13 s for a square pattern.

What are the limits of the calculator?

The calculator gives the radial consolidation of an ideal drain. It does not include the smear zone around the drain, which makes the consolidation slower, the well resistance of long drains, the vertical drainage that adds to the radial one, the secondary compression or the change of ch with the stress. The design with drains needs the field monitoring with settlement plates and piezometers.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.