The floor walking vibration calculator gives the peak acceleration caused by walking on a floor, the ratio to the acceptance limit and the effective weight needed to meet it, from the natural frequency, the effective weight, the damping and the use of the floor.
How the calculation works
- Enter the natural frequency and the effective weight of the floor panel.
- Choose the damping ratio and the acceptance limit for the use of the floor.
- The calculator finds the peak acceleration from walking, the ratio to the limit and the effective weight needed to meet the limit.
Example
A floor with a natural frequency of 8 Hz, an effective weight of 30,000 lb and a damping of 3 percent has a peak acceleration of 65 × e^(−0.35 × 8) / (0.03 × 30,000) = 0.44 percent of g. For an office the limit is 0.5 percent, so the ratio is 0.88 and the floor is acceptable. To reach the limit the floor needs an effective weight of at least 26,351 lb.
Why it matters
The calculator helps structural engineers, floor designers, architects and students to check the walking comfort of a steel or concrete floor in the early design, to see the effect of the damping and the weight, and to decide whether to stiffen the floor.
Good to know
Raise the frequency of the floor above 8 Hz when you can, since it has the largest effect. Add stiffness to the beams and the girders, use a thicker slab, and count the non-structural partitions in the damping only if they will stay in place. Compute the frequency with the floor natural frequency calculator, then use this value here, and ask for a full analysis if the ratio is over 0.8.
Related tools
The floor natural frequency calculator gives the frequency of a floor panel, the floor load calculator gives the loads of a floor, the vibration isolation calculator sizes the mounts of a machine and the tuned mass damper calculator sizes a damper for a structure.