Skip to content
Omnikalc

SCS triangular hydrograph calculator: peak discharge and runoff volume of a watershed

Enter the rainfall depth, the curve number, the drainage area and the time of concentration to get the runoff depth, the time to peak, the peak discharge, the base time and the runoff volume of the SCS triangular hydrograph.

Updated on
Your inputs
in

Value out of range

Value out of range

mi²

Value out of range

h

Value out of range

Results

Peak discharge

1,977 cfs

Runoff depth
2.04 in
Time to peak
1.00 h
Base time of the hydrograph
2.67 h
Runoff volume
217.8 acre-ft

The SCS triangular hydrograph calculator gives the runoff depth, the time to peak, the peak discharge, the base time and the runoff volume of a watershed by the NRCS curve number method and the 484 peak rate factor, from the rainfall, the curve number, the area and the time of concentration.

How the calculation works

  • Enter the rainfall depth of the design storm, the curve number of the watershed and its area.
  • Enter the time of concentration of the watershed.
  • The calculator finds the runoff depth with the SCS method, the time to peak, the peak discharge of the triangular unit hydrograph with the factor 484, the base time and the runoff volume.

Example

A watershed of 2 mi² has a curve number of 80 and a time of concentration of 1.5 h. The storm gives 4 in of rain. The retention is S = 1000 / 80 − 10 = 2.5 in, the initial abstraction is 0.5 in and the runoff is (4 − 0.5)² / (4 + 0.8 × 2.5) = 2.04 in. The time to peak is 0.133 × 1.5 / 2 + 0.6 × 1.5 = 1.00 h. The peak is 484 × 2 × 2.04 / 1.00 = 1,977 cfs, the base time is 2.67 × 1.00 = 2.67 h and the volume is 2.04 / 12 × 2 × 640 = 217.8 acre-ft.

Why it matters

The calculator helps drainage engineers, land developers, planners and students to estimate the peak flow and the volume of a design storm on a watershed, for a culvert, a channel or a detention pond, and to see how the curve number and the time of concentration change the result.

Good to know

Use the curve number of the developed condition and the time of concentration of the longest flow path. Compare the result with the rational method for small areas. Check that the area is not too large for the method, since a very large watershed is divided into subareas and routed.

The SCS curve number calculator gives the runoff depth, the time of concentration calculator gives the travel time, the rational method calculator gives the peak for small areas and the detention time calculator checks the storage.

Frequently asked questions

What is the SCS triangular hydrograph?

The SCS (NRCS) triangular unit hydrograph is a simplified shape of the runoff hydrograph of a watershed. It rises to a peak at the time to peak, then falls to zero at a base time equal to 2.67 times the time to peak. The area under the triangle is the runoff volume. The shape is used in TR-55 and in many local drainage manuals to size detention ponds and culverts when no gauged data exist.

How is the peak discharge found?

The calculator first finds the runoff depth from the rainfall and the curve number, with S = 1000/CN − 10 and an initial abstraction of 0.2 S. The lag is 0.6 times the time of concentration, the storm duration of the unit hydrograph is 0.133 times the time of concentration, and the time to peak is half this duration plus the lag. The peak is qp = 484 A Q / tp for A in square miles, Q in inches and tp in hours, which gives cfs.

What does the factor 484 mean?

The factor 484 is the peak rate factor of a standard dimensionless hydrograph, in which 37.5 % of the volume comes before the peak. It is suited to average watersheds. A flat and swampy terrain uses a lower factor, such as 300 or less, and a steep terrain uses a higher one, up to 600. This calculator uses 484 (0.208 in SI units), as the default of the method.

What are the limits of the calculator?

The method gives only the peak and the triangular shape of a single storm. It does not include the routing through the ponds and the channels, the snowmelt, the antecedent moisture, the varying rainfall intensity during the storm or the effect of a non uniform watershed. For a detention pond design, a complete hydrologic model should be used and reviewed by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.