Skip to content
Omnikalc

Geotextile filter calculator: check the opening size and the permeability of a filter fabric

Enter the D85 and Cu of the soil, the AOS and the permeability of the geotextile and the permeability of the soil to get the factor B, the maximum opening, the retention ratio and the permeability margin.

Updated on
Your inputs
mm

Value out of range

Value out of range

mm

Value out of range

cm/s

Value out of range

cm/s

Value out of range

Results

Retention ratio O95 / (B × D85)

0.44

Retention criterion met: the geotextile holds the soil
Factor B for the soil
1.60
Maximum opening size B × D85
0.480 mm
Permeability margin (kg / ks) / required
2.00
Permeability criterion met

The geotextile filter calculator gives the factor B, the maximum opening size, the retention ratio and the permeability margin of a filter fabric for drains, riprap and retaining walls, from the grading of the soil and the properties of the geotextile.

How the calculation works

  • Enter the D85 and the coefficient of uniformity Cu of the soil to be filtered.
  • Enter the apparent opening size O95 and the permeability of the geotextile, and the permeability of the soil.
  • Choose the application, critical or not. The calculator finds the factor B, the maximum opening size, the retention ratio and the permeability margin of the geotextile filter.

Example

A geotextile filters a soil with D85 = 0.30 mm and Cu = 5. Since 4 < Cu < 8, the factor is B = 8 / 5 = 1.6 and the maximum opening is 1.6 × 0.30 = 0.480 mm. The geotextile has O95 = 0.212 mm, so the retention ratio is 0.212 / 0.480 = 0.44. The permeability of the geotextile is 0.2 cm/s and that of the soil 0.01 cm/s, so kg / ks = 20, and for a critical application (factor 10) the margin is 20 / 10 = 2.00.

Why it matters

The calculator helps geotechnical engineers, civil designers, contractors and students to choose or check a filter geotextile in a first design, to see if the opening size retains the soil and if the permeability is enough.

Good to know

Test the real grading of the soil, including the fines, and choose a product with a margin on both criteria. Protect the geotextile from the damage during the installation, overlap or sew the seams, and add a clogging test for the severe applications and for the soils with many fines.

The Darcy’s law calculator gives the flow in the soil, the riprap calculator sizes the stone over the geotextile, the soil gradation calculator gives Cu and D85 and the infiltration trench calculator sizes a stone reservoir lined with a geotextile.

Frequently asked questions

What does a geotextile filter do?

A filter geotextile lets the water pass and keeps the soil in place. It replaces the graded sand filter in drains, behind retaining walls, under riprap and in trench drains. It must retain the soil particles, so that the soil does not wash out, and it must let the water flow, so that the water pressure does not build up behind it. It must also resist the clogging in the long term.

What is the retention criterion?

The retention criterion compares the apparent opening size of the geotextile, O95, with the D85 of the soil: O95 ≤ B D85. The factor B depends on the coefficient of uniformity Cu of the soil: B = 1 for Cu ≤ 2 or Cu ≥ 8, B = 0.5 Cu for 2 < Cu < 4, and B = 8/Cu for 4 ≤ Cu ≤ 8. This criterion is for a soil with less than 50 % passing the 0.075 mm sieve and a steady flow. Fine soils and dynamic flows need stricter rules.

What is the permeability criterion?

The permeability of the geotextile must be higher than that of the soil, kg ≥ ks, for the non critical applications, and kg ≥ 10 ks for the critical or severe ones, such as the drains of dams or of deep walls, and the soils that are susceptible to clogging. The test with the permittivity of the product and the thickness gives kg. A margin protects the system against the partial clogging during the life of the structure.

What are the limits of the calculator?

The calculator applies the basic retention and permeability criteria for a soil with less than 50 % fines. It does not include the clogging resistance test, the survivability and the strength of the geotextile during the installation, the dispersive and gap graded soils, the dynamic flows or the chemical and biological clogging. A filter design in a major structure must follow the specification and be reviewed by a geotechnical engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.