Skip to content
Omnikalc

Infiltration trench calculator: size of a stone reservoir for stormwater

Enter the drainage area, the design rainfall, the porosity and depth of the stone and the soil infiltration rate to get the runoff volume, the stone volume, the footprint of the trench and the drawdown time.

Updated on
Your inputs
acres

Value out of range

in

Value out of range

Value out of range

Value out of range

ft

Value out of range

in/h

Value out of range

Results

Trench footprint area

2,246 ft²

Runoff volume to store
3,594 ft³
Stone volume required
8,984 ft³
Drawdown time of the trench
38.4 h
Drains within 48 h, which meets most stormwater rules

The infiltration trench calculator gives the runoff volume to store, the stone volume, the footprint area and the drawdown time of a stormwater infiltration trench, from the drainage area, the design rainfall, the porosity of the stone and the infiltration rate of the soil.

How the calculation works

  • Enter the impervious drainage area, the design rainfall depth (for example the water quality storm) and the runoff coefficient.
  • Enter the porosity of the stone, the depth of the stone reservoir and the design infiltration rate of the soil at the bottom.
  • The calculator finds the runoff volume to store, the stone volume required, the footprint area of the trench and its drawdown time.

Example

An area of 1 acre with a runoff coefficient of 0.9 receives 1.1 in of rain. The runoff is 0.9 × 1.1 / 12 × 1 × 43,560 = 3,594 ft³. With a stone porosity of 0.4, the stone volume is 3,594 / 0.4 = 8,984 ft³. For a reservoir depth of 4 ft, the footprint is 8,984 / 4 = 2,246 ft². With a design infiltration rate of 0.5 in/h, the drawdown time is 4 × 0.4 / (0.5 / 12) = 38.4 h.

Why it matters

The calculator helps civil engineers, landscape architects, site designers, contractors and students to size an infiltration trench for a water quality or a volume control requirement, to compare the depth and the footprint, and to check the drawdown time before a soil test or a detailed design.

Good to know

Locate the trench away from foundations, on a soil that was not compacted, and protect it from sediment during the construction. Add an observation well to see the drawdown, an overflow for the large storms, and a pretreatment for the sediment. Check the drawdown time against the local limit.

The rain garden calculator sizes a planted basin, the dry well calculator sizes a pit for a roof, the water quality volume calculator gives the volume to treat and the Darcy’s law calculator gives the flow through a soil.

Frequently asked questions

What is an infiltration trench?

An infiltration trench is a long and narrow excavation filled with clean stone, wrapped in a geotextile, which receives the runoff from a roof, a parking lot or a road and lets it soak into the ground. The water is stored in the voids between the stones during the storm, then infiltrates through the bottom and the sides. It reduces the runoff volume, recharges the groundwater and removes part of the pollutants.

How is the trench sized?

The calculator stores the whole design runoff volume in the voids of the stone, which is conservative because it ignores the infiltration during the storm. The stone volume is the runoff volume divided by the porosity, and the footprint is the stone volume divided by the depth. The drawdown time is the depth of the water in the voids, which is the depth of stone times the porosity, divided by the infiltration rate.

What infiltration rate should be used?

Use the rate measured by a field test at the depth of the bottom of the trench, with a safety factor of 2 or more, because the rate falls with the clogging by fines. Many manuals do not allow infiltration in soils slower than 0.5 in/h (13 mm/h) or faster than 8 in/h, because of the risk for the groundwater. The seasonal high water table must be at least 2 to 4 ft (0.6 to 1.2 m) under the bottom.

What are the limits of the calculator?

The calculator does not include the inflow routing, the infiltration through the sides, the overflow of larger storms, the pretreatment of the sediment, or the setbacks from foundations and wells. A trench receiving runoff with sediment needs a pretreatment such as a sump or a grass strip. The design must follow the local stormwater manual and be reviewed by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.