Skip to content
Omnikalc

Glulam beam volume factor and bending capacity calculator

Enter the bending value, the width, the depth, the span, the species group, the duration factor and the load to get the volume factor, the allowable moment and the ratio.

Updated on
Your inputs
psi

Value out of range

in

Value out of range

in

Value out of range

ft

Value out of range

Value out of range

Value out of range

plf

Value out of range

Results

Ratio of the moment to the allowable

0.86

The beam can carry the bending moment
Volume factor
0.927
Adjusted bending design value
2,557 psi
Section modulus
277 in³
Allowable moment
59.0 kip-ft
Applied moment
50.6 kip-ft

The glulam beam volume factor and bending capacity calculator gives the volume factor, the adjusted bending design value, the section modulus, the allowable moment, the applied moment and the ratio of a simple span glulam beam, from the size, the span, the species group and the load.

How the calculation works

  • Enter the reference bending value, the width, the depth and the span of the glulam beam.
  • Choose the species group and enter the load duration factor, the stability factor and the load.
  • The calculator finds the volume factor, the adjusted bending value, the allowable moment and the ratio.

Example

A glulam beam of 5.125 × 18 in on a span of 30 ft of a western species has a volume factor of (21 / 30)^0.1 × (12 / 18)^0.1 × 1 = 0.927. With Fb = 2,400 psi and a load duration factor of 1.15, the adjusted value is 2,557 psi. The section modulus is 277 in³, so the allowable moment is 59.0 kip-ft. A load of 450 plf gives 50.6 kip-ft, a ratio of 0.86.

Why it matters

The calculator helps structural engineers, builders, timber designers and students to check a glulam beam in bending, to see how the size and the span change the volume factor, and to compare several sections before the detailed design.

Good to know

Specify the grade and the layup of the glulam beam in the drawings, with the side of the beam which has to be in tension. Check also the shear, the bearing and the deflection, and use a camber to offset the dead load. Protect the beam from the moisture during the storage and the erection, and brace the compression edge as the design requires.

The wood beam span calculator checks a sawn timber beam, the wood column capacity calculator checks a column, the beam deflection calculator gives the deflection and the timber char depth and fire rating calculator gives the fire resistance of a large timber member.

Frequently asked questions

What is the volume factor?

The volume factor CV reduces the bending value of a glulam beam when the beam is bigger than the reference size of 5.125 in wide, 12 in deep and 21 ft long. It takes into account that a larger beam has a greater chance of having a weak spot, so its strength is lower. It is the product of three terms, the span, the depth and the width, each raised to the power 1 divided by x, where x is 10 for the western species and 20 for the southern pine.

What is the load duration factor?

Wood can carry a higher load for a short time than for a long time. The load duration factor adjusts the design value: 0.9 for a permanent load, 1.0 for ten years, 1.15 for two months as the snow load, 1.25 for seven days, 1.6 for the wind and the earthquake and 2.0 for the impact. The factor is for the load which has the shortest duration in the combination.

Why take the lesser of CL and CV?

In the design of a glulam beam for the bending, the volume factor and the beam stability factor are not applied together. The lesser of the two is used, because the two effects, the size of the beam and the buckling to the side, are not independent. A beam with a continuous lateral support has CL = 1, and the volume factor is then the one which governs.

What are the limits of the calculator?

The calculator checks the bending of a simple span for the tension zone stressed in tension, with the factors that you enter. It does not check the shear, the bearing, the deflection, the camber, the fire resistance, the moisture, the temperature, the flat use or the connections. The design values must come from the standard and from the grade of the manufacturer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.