Timber char depth calculator: fire resistance of exposed heavy timber members

Enter the member width and depth, the fire resistance time and the number of exposed sides to get the char depth, the effective char depth and the remaining section, section modulus and area.

Updated on
Your inputs
in

Value out of range

in

Value out of range

Results

Section modulus remaining

33.7 %

A large part of the section is lost: check the loads against the remaining section
Char depth (NDS)
1.50 in
Effective char depth (char plus the layer with zero strength)
1.80 in
Width of the remaining section
3.15 in
Depth of the remaining section
10.20 in
Area remaining
39.7 %

The timber char depth calculator gives the char depth and the remaining section of a wood beam or column after a fire of a given duration, from the NDS method, with the section modulus and area that remain.

How the calculation works

  • Enter the width and the depth of the timber beam or column.
  • Choose the required fire resistance (30 minutes to 2 hours) and the number of exposed sides.
  • The calculator finds the char depth a = 1.5 t^0.813 from the NDS and the effective char depth 1.2 a, which includes the heated layer with no strength.
  • It gives the remaining section, the section modulus and the area retained after the fire exposure.

Example

A glulam beam of 6.75 in × 12 in is exposed on 3 sides for 1 hour. The char depth is 1.5 × 1^0.813 = 1.50 in, and the effective char depth is 1.2 × 1.5 = 1.80 in. The remaining section is 3.15 in wide (6.75 − 2 × 1.8) and 10.20 in deep (12 − 1.8). The section modulus retained is 3.15 × 10.2² / (6.75 × 12²) = 33.7% and the area retained is 39.7%.

Why it matters

The calculator helps structural engineers, architects, builders and students to check the fire resistance of heavy timber and glulam members, to choose a member size for a rating of 30 minutes to 2 hours and to compare it with steel and with protected solutions. It supports the first design of exposed timber structures.

Good to know

Add the effective char depth on all exposed faces, including the corners, which are rounded in a real fire. Check that the remaining section still carries the load of the fire design situation, and protect the connections and steel plates. Consider the rate of an engineered product such as cross-laminated timber, which can differ from solid wood. A fire engineer or the building official must approve the design.

The wood beam span calculator sizes timber beams, the beam deflection calculator covers deflection, the steel column capacity calculator covers steel and the Euler buckling calculator covers column buckling.

Frequently asked questions

How does wood resist fire?

A large timber member burns on the outside and the char layer insulates the wood behind it, so the core stays cool and keeps its strength. The char forms at a nearly constant rate, about 1.5 in per hour (38 mm/h) for most softwoods. A heavy timber beam can therefore resist a fire for an hour or more, while a steel beam without protection loses its strength within 15 to 30 minutes.

What is the effective char depth?

The wood just behind the char line is heated and weakened. The NDS accounts for this with the effective char depth, which is the char depth times 1.2 for the one-hour rating, and so the strength of the member is calculated on the section reduced by the effective char depth on each exposed face. The Eurocode 5 does the same by adding a layer of 7 mm with zero strength to the char depth.

Which sides are exposed?

A beam under a floor, with the top protected by the deck, is exposed on three sides: the bottom and the two faces. A free-standing column, or a beam with the floor above it burned through, is exposed on four sides. The faces protected by gypsum board or by another member are not charred during the protection time. The calculator takes the cases of three and four sides.

Is the section enough?

The remaining section must carry the design load of the fire situation, using average strengths and not the allowable stresses reduced by the safety factors. The check of the remaining section is a structural calculation by an engineer. The percentage of section modulus and area shown here is a quick indicator, and the connections and the fasteners must be protected too.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.