Helical pile calculator: capacity from the installation torque

Enter the installation torque, the torque factor, the factor of safety and the design load to get the ultimate and allowable capacity, the minimum torque and the load ratio.

Updated on
Your inputs
ft-lb

Value out of range

Value out of range

kip

Value out of range

Results

Allowable capacity

30.0 kip

Ultimate capacity
60.0 kip
Minimum torque for the design load
4,000 ft-lb
Ratio of design load to allowable
0.67
The helical pile has enough capacity

The helical pile calculator gives the ultimate capacity, the allowable capacity, the minimum installation torque for a design load and the load ratio of a helical pile, from the final installation torque and the torque correlation factor Kt.

How the calculation works

  • Enter the final installation torque read on the torque indicator during the last feet of installation.
  • Choose the torque correlation factor that matches the shaft of the pile, enter the factor of safety and the design load.
  • The calculator finds the ultimate capacity, the allowable capacity, the minimum torque needed for the design load and the ratio of the load to the capacity.

Example

A helical pile with a square shaft (Kt = 10 ft⁻¹) is installed with a final torque of 6,000 ft-lb. The ultimate capacity is 10 × 6,000 = 60,000 lb, or 60.0 kip. With a factor of safety of 2, the allowable capacity is 30.0 kip. For a design load of 20 kip, the minimum torque is 2 × 20,000 / 10 = 4,000 ft-lb, and the ratio of the load to the allowable capacity is 0.67.

Why it matters

The calculator helps foundation contractors, geotechnical and structural engineers, inspectors and students to check each helical pile on site, to find the torque to reach before stopping the installation, and to compare the capacity with the load of a deck, a solar array or a retrofit.

Good to know

Read the torque in the last three diameters of the helix, with a calibrated indicator, and never use the peak value of a single reading. Verify that the pile reaches the design depth in the bearing stratum as well as the torque, and keep the records of every pile. Run a load test on one or two piles of the job to confirm the correlation factor and to get a more economical design when the number of piles is large.

The pile capacity calculator uses the soil strength for driven piles, the drilled shaft capacity calculator gives the bored shafts, the soil unit weight calculator converts the soil data and the torque calculator helps to size the drive tool.

Frequently asked questions

What is the torque correlation method?

The torque correlation method says that the ultimate capacity of a helical pile, in tension or in compression, is equal to the final installation torque times an empirical factor Kt. The idea is that the torque needed to screw the pile into the soil is related to the shear strength of the soil around the helices, which is also what gives the capacity. The method is simple and is used on site as a quality check of each pile.

What values of Kt are used?

The model codes and the evaluation reports give 10 ft⁻¹ (33 m⁻¹) for square shafts up to 2.5 in, 7 ft⁻¹ (23 m⁻¹) for round shafts of 2.875 to 3.5 in, and 3 ft⁻¹ (10 m⁻¹) for larger round shafts. The real value can be different for a given product, and the manufacturer may publish a tested value. A pile with a larger shaft has a lower factor because the shaft skin adds torque without adding capacity.

What factor of safety should be used?

A minimum factor of safety of 2 is common for the allowable capacity of helical piles, and codes can require a higher value when there is no load test. The design capacity should also be checked against the structural capacity of the shaft, the couplings and the helix plates, and against the bearing of the helices computed from the soil data, and the lowest value governs.

What are the limits of the calculator?

The calculator uses the torque only and does not check the individual helices, the settlement, the buckling of a slender shaft in a soft soil, the lateral load, the corrosion, the group effects or the depth needed to be below the weak layers. A torque in a fill or in a very soft soil may not be a good indicator, and a load test is the best way to confirm the capacity.