Skip to content
Omnikalc

Tremie seal thickness calculator: uplift, factor of safety and concrete volume

Enter the water head, the seal thickness, the concrete weight, the bond, the area and the required factor to get the uplift, the factor of safety, the thickness needed and the volume.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

pcf

Value out of range

psf

Value out of range

ft²

Value out of range

Value out of range

Results

Thickness needed

9.29 ft

Uplift pressure on the seal
1,248 psf
Resisting pressure
1,600 psf
Factor of safety
1.28
Ratio of the needed thickness to the thickness placed
0.93
The seal is thick enough for the required factor
Concrete volume of the seal
333.3 yd³

The tremie seal calculator gives the uplift pressure, the resisting pressure, the factor of safety, the thickness needed and the concrete volume of an underwater concrete seal at the bottom of a cofferdam, from the water head, the thickness and the bond.

How the calculation works

  • Enter the water head on the underside of the seal, the thickness placed and the unit weight of the underwater concrete.
  • Enter the bond and friction of the walls and the piles, the area of the seal and the required factor of safety.
  • The calculator finds the uplift pressure, the resisting pressure, the factor of safety, the thickness needed and the volume of the seal.

Example

A tremie seal has a water head of 20 ft on its underside, so the uplift is 62.4 × 20 = 1,248 psf. The seal is 10 ft thick and the concrete weighs 145 pcf, with a bond of 150 psf, so the resistance is 145 × 10 + 150 = 1,600 psf and the factor of safety is 1.28. For a required factor of 1.2, the thickness needed is (1.2 × 1,248 − 150) / 145 = 9.29 ft, a ratio of 0.93. The volume of a seal of 900 ft² is 333.3 yd³.

Why it matters

The calculator helps bridge and marine engineers, contractors and students to check if a tremie seal is thick enough to resist the uplift once the cofferdam is dewatered, to find the thickness for a given factor of safety, and to estimate the volume of concrete to order for the pour.

Good to know

Keep the tremie pipe embedded in the fresh concrete by at least 3 ft, 1 m, at all times, and fill the pipe with a plug so that the first concrete does not mix with the water. Use a concrete with a slump of 6 to 8 in, a high cement content and a retarder. Clean the laitance after the cure, and check the seal with the divers or the cores before the dewatering.

The buried tank flotation calculator checks a structure against the uplift of the groundwater, the mass concrete temperature calculator checks the heat of a large pour, the ready-mix truck fleet size calculator sizes the supply of concrete and the trench dewatering calculator sizes the pumping of an excavation.

Frequently asked questions

What is a tremie seal?

A tremie seal is a slab of concrete placed under water through a tremie pipe, usually at the bottom of a cofferdam, of a caisson or of a pier foundation. When the cofferdam is pumped dry, the seal resists the water pressure from below and gives a dry base for the construction of the footing. The pipe stays buried in the fresh concrete, so that the concrete flows out without mixing with the water.

How is the uplift resisted?

The seal resists the uplift of the water with its own weight and, if the seal is bonded to the piles or to the walls of the cofferdam, with the bond or the friction on them. The water pressure is the unit weight of the water times the head on the underside of the seal. The factor of safety is the ratio of the resistance to the uplift, and a value of 1.2 or more is common for the temporary works.

What unit weight is used?

The underwater concrete is rich in cement and contains admixtures, and it is placed without vibration. Its unit weight is often a little lower than that of the usual concrete, about 145 pcf or 23 kN/m³. The calculator compares the total weight of the seal with the full water pressure at its underside, so that the buoyancy is not subtracted a second time from the weight.

What are the limits of the calculator?

The calculator makes the balance of the vertical forces of a seal. It does not check the bending of the seal between the piles, the shear at the piles, the lateral pressure on the cofferdam, the quality of the concrete or the placement of the concrete under water. The thickness of the seal must also allow for the laitance on the top, which is removed, and for the rough level of the underwater surface.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.