The masonry wall axial capacity calculator gives the slenderness ratio, the reduction factor, the allowable axial load and the demand to capacity ratio of a reinforced masonry wall by the TMS 402 allowable stress method, from the thickness, the strength, the steel and the height.
How the calculation works
- Enter the thickness of the wall, the solid fraction of its cross section (grouting), the specified strength f’m and the vertical steel per foot of wall.
- Enter the allowable steel stress, the effective height of the wall and the axial load applied per foot of wall.
- The calculator finds the slenderness ratio, the reduction factor, the allowable axial load by the TMS 402 allowable stress formula and the demand to capacity ratio.
Example
A fully grouted CMU wall of 7.625 in with f’m = 2000 psi, 0.155 in²/ft of steel at 24,000 psi and an effective height of 12 ft has r = 0.289 × 7.625 = 2.204 in and h/r = 144 / 2.204 = 65.3. The reduction factor is 1 − (144 / (140 × 2.204))² = 0.782. The allowable load is (0.25 × 2000 × 91.5 + 0.65 × 0.155 × 24,000) × 0.782 = 37,674 lb/ft. For an applied load of 15,000 lb/ft, the ratio is 0.40.
Why it matters
The calculator helps structural engineers, masonry designers, builders and students to check a bearing wall of concrete block in a first design, to see the effect of the height and the thickness, and to decide if a wall needs grout, more steel or a thicker block.
Good to know
Keep the loads close to the center of the wall, check the combined axial and bending, and use the net area and the radius of gyration of the real units for the final design. Confirm the strength f’m with the prism tests or the unit strength table.
Related tools
The masonry lintel calculator checks the openings, the Euler buckling calculator gives the elastic buckling load, the concrete block fill calculator estimates the grout and the beam bearing length calculator checks the bearing under beams.