Skip to content
Omnikalc

Masonry wall axial capacity calculator: allowable load of a reinforced masonry wall

Enter the wall thickness, the grouting, the masonry strength, the vertical steel, the height and the applied load to get the slenderness, the reduction factor, the allowable axial load and the demand to capacity ratio.

Updated on
Your inputs
in

Value out of range

psi

Value out of range

in²/ft

Value out of range

psi

Value out of range

ft

Value out of range

lb/ft

Value out of range

Results

Allowable axial load

37,674 lb/ft

Slenderness ratio h/r
65.3
Slenderness within the limit of the formula (h/r of 99 or less)
Slenderness reduction factor
0.782
Demand to capacity ratio
0.40
Applied load within the allowable load

The masonry wall axial capacity calculator gives the slenderness ratio, the reduction factor, the allowable axial load and the demand to capacity ratio of a reinforced masonry wall by the TMS 402 allowable stress method, from the thickness, the strength, the steel and the height.

How the calculation works

  • Enter the thickness of the wall, the solid fraction of its cross section (grouting), the specified strength f’m and the vertical steel per foot of wall.
  • Enter the allowable steel stress, the effective height of the wall and the axial load applied per foot of wall.
  • The calculator finds the slenderness ratio, the reduction factor, the allowable axial load by the TMS 402 allowable stress formula and the demand to capacity ratio.

Example

A fully grouted CMU wall of 7.625 in with f’m = 2000 psi, 0.155 in²/ft of steel at 24,000 psi and an effective height of 12 ft has r = 0.289 × 7.625 = 2.204 in and h/r = 144 / 2.204 = 65.3. The reduction factor is 1 − (144 / (140 × 2.204))² = 0.782. The allowable load is (0.25 × 2000 × 91.5 + 0.65 × 0.155 × 24,000) × 0.782 = 37,674 lb/ft. For an applied load of 15,000 lb/ft, the ratio is 0.40.

Why it matters

The calculator helps structural engineers, masonry designers, builders and students to check a bearing wall of concrete block in a first design, to see the effect of the height and the thickness, and to decide if a wall needs grout, more steel or a thicker block.

Good to know

Keep the loads close to the center of the wall, check the combined axial and bending, and use the net area and the radius of gyration of the real units for the final design. Confirm the strength f’m with the prism tests or the unit strength table.

The masonry lintel calculator checks the openings, the Euler buckling calculator gives the elastic buckling load, the concrete block fill calculator estimates the grout and the beam bearing length calculator checks the bearing under beams.

Frequently asked questions

How is the axial capacity of a masonry wall found?

In the allowable stress design of TMS 402, the allowable axial load of a reinforced wall is Pa = (0.25 f'm An + 0.65 As Fs) [1 − (h/140r)²] for h/r not above 99. The first term is the contribution of the net area of the masonry, the second one of the compression steel, and the last factor reduces the capacity for the slenderness of the wall. The load must be applied with a small eccentricity.

What is the radius of gyration?

The radius of gyration r is the square root of the ratio of the moment of inertia to the area of the section. For a rectangular section of thickness t, it is 0.289 t. For a hollow unit wall, the true value depends on the face shells and the grout, and the code gives tables of the net area and of the moment of inertia of the units. The calculator uses the thickness for a simple estimate.

Why does the slenderness matter?

A tall thin wall can buckle before it crushes. The factor 1 − (h/140r)² reduces the capacity quickly: it is 0.78 for h/r of 65 and 0.50 for h/r of 99. For h/r above 99, the capacity is given by the Euler type formula (70r/h)², and the wall is very slender, so the effects of the eccentricity and the lateral loads become important.

What are the limits of the calculator?

The calculator gives the axial capacity of a wall under a concentric load only. It does not include the combined bending of wind or earthquake, the eccentricity of the roof or floor, the shear, the different strength of the units and the grout, the bearing, or the strength design method. A masonry wall must be designed by a licensed engineer according to the code.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.