The Mononobe-Okabe calculator gives the static coefficient Ka, the seismic coefficient KAE, the static and total active forces, the seismic increment and its height for a retaining wall with a vertical back and a level cohesionless backfill.
How the calculation works
- Enter the height of the wall, the unit weight and the friction angle of the backfill, and the friction angle between the wall and the soil.
- Enter the horizontal seismic coefficient kh, often 0.5 times the peak ground acceleration in g, and the vertical coefficient kv, often 0.
- The calculator finds the static coefficient Ka, the seismic coefficient KAE of Mononobe and Okabe, the active forces, the seismic increment and the height at which it acts.
Example
A vertical wall of 20 ft retains a level backfill of 120 pcf with φ = 34° and a wall friction angle of 17°. The static coefficient is Ka = 0.256 and the force is 0.5 × 120 × 20² × 0.256 = 6,155 lb/ft. With kh = 0.15 and kv = 0, the coefficient is KAE = 0.353 and the total force is 0.5 × 120 × 20² × 0.353 = 8,472 lb/ft. The seismic increment is 2,317 lb/ft, applied at 0.6 × 20 = 12.0 ft above the base.
Why it matters
The calculator helps geotechnical and structural engineers, designers and students to estimate the earthquake force on a retaining or basement wall in a first design, and to see how the seismic coefficient, the friction angle and the wall friction change the force.
Good to know
Choose kh with the displacement criteria of the code, check the sliding, the overturning and the bearing with the seismic force, and add the surcharge and the water pressure where they exist. For tall walls and for important structures, compare the result with a dynamic analysis.
Related tools
The Rankine earth pressure calculator gives the static pressure, the retaining wall calculator checks the stability, the seismic base shear calculator gives the earthquake force on a building and the liquefaction factor of safety calculator checks the soil.