Skip to content
Omnikalc

Mononobe-Okabe calculator: seismic active earth pressure on a retaining wall

Enter the wall height, the soil unit weight and friction angles and the seismic coefficients to get Ka, KAE, the static and total active forces, the seismic increment and its height.

Updated on
Your inputs
ft

Value out of range

pcf

Value out of range

°

Value out of range

°

Value out of range

Value out of range

Value out of range

Results

Total active force with earthquake PAE

8,472 lb/ft

Static active coefficient Ka
0.256
Seismic active coefficient KAE
0.353
Static active force PA
6,155 lb/ft
Seismic increment ΔPAE
2,317 lb/ft
Height of ΔPAE above the base
12.0 ft

The Mononobe-Okabe calculator gives the static coefficient Ka, the seismic coefficient KAE, the static and total active forces, the seismic increment and its height for a retaining wall with a vertical back and a level cohesionless backfill.

How the calculation works

  • Enter the height of the wall, the unit weight and the friction angle of the backfill, and the friction angle between the wall and the soil.
  • Enter the horizontal seismic coefficient kh, often 0.5 times the peak ground acceleration in g, and the vertical coefficient kv, often 0.
  • The calculator finds the static coefficient Ka, the seismic coefficient KAE of Mononobe and Okabe, the active forces, the seismic increment and the height at which it acts.

Example

A vertical wall of 20 ft retains a level backfill of 120 pcf with φ = 34° and a wall friction angle of 17°. The static coefficient is Ka = 0.256 and the force is 0.5 × 120 × 20² × 0.256 = 6,155 lb/ft. With kh = 0.15 and kv = 0, the coefficient is KAE = 0.353 and the total force is 0.5 × 120 × 20² × 0.353 = 8,472 lb/ft. The seismic increment is 2,317 lb/ft, applied at 0.6 × 20 = 12.0 ft above the base.

Why it matters

The calculator helps geotechnical and structural engineers, designers and students to estimate the earthquake force on a retaining or basement wall in a first design, and to see how the seismic coefficient, the friction angle and the wall friction change the force.

Good to know

Choose kh with the displacement criteria of the code, check the sliding, the overturning and the bearing with the seismic force, and add the surcharge and the water pressure where they exist. For tall walls and for important structures, compare the result with a dynamic analysis.

The Rankine earth pressure calculator gives the static pressure, the retaining wall calculator checks the stability, the seismic base shear calculator gives the earthquake force on a building and the liquefaction factor of safety calculator checks the soil.

Frequently asked questions

What is the Mononobe-Okabe method?

The Mononobe-Okabe (M-O) method is a pseudo-static extension of the Coulomb theory of the active earth pressure to the earthquake loads. The inertia of the soil wedge behind the wall is replaced by a horizontal force kh W and a vertical force kv W, which tilt the weight of the wedge. The result is a seismic active coefficient KAE that is higher than the static one. It is used for gravity walls, cantilever walls and basement walls in the codes.

How is the seismic coefficient chosen?

The horizontal coefficient kh depends on the seismic hazard and on the amount of displacement that the wall can tolerate. For a wall that can move 1 to 2 in (25 to 50 mm), kh is often taken as 0.5 times the peak ground acceleration divided by g, as in the AASHTO bridge specifications. For a rigid wall that cannot move, kh is taken equal to the peak acceleration. The vertical coefficient is usually ignored or taken as one half to two thirds of kh.

Where does the seismic increment act?

The static force PA acts at one third of the height from the base. The seismic increment ΔPAE = PAE − PA acts higher, at about 0.6 H from the base, according to Seed and Whitman, while the full M-O force would act at the mid height. The calculator gives the increment and its height, so that the moment on the base and the stability of the wall can be found with the static and the seismic parts separately.

What are the limits of the calculator?

The calculator covers a vertical wall with a level, dry and cohesionless backfill. It does not include a sloping backfill, the water pressure, the cohesion, the surcharge, the passive resistance, the dynamic effects of the wall response or the liquefaction. Walls that can not be designed with the pseudo-static method, such as the walls on liquefiable soils, need a special analysis by a geotechnical engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.