Skip to content
Omnikalc

Parshall flume discharge calculator: open channel flow from one head measurement

Choose the throat width and enter the upstream and downstream heads to get the discharge in cfs, gpm and MGD and the submergence ratio that tells whether the flow is free.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

Results

Discharge

15.97 cfs

Discharge in gallons per minute
7,166 gpm
Discharge in million gallons per day
10.32 MGD
Submergence ratio Hb/Ha
0.60
The flow is free: the formula applies

The Parshall flume discharge calculator gives the flow in an open channel from the throat width of the flume and the upstream head, in cfs, gpm and MGD, with the submergence ratio that shows whether the free flow equation applies.

How the calculation works

  • Choose the throat width of the Parshall flume, which sets the range of flow.
  • Enter the upstream head Ha, measured in the converging section at the gauge point, and the downstream head Hb at the throat.
  • The calculator finds the free-flow discharge with the standard equation Q = 4 W Ha^(1.522 W^0.026), in cfs, gpm and MGD, and the submergence ratio Hb/Ha, which should stay under 0.7 for free flow.

Example

A 3 ft Parshall flume has an upstream head of 1.20 ft and a downstream head of 0.72 ft. The exponent is 1.522 × 3^0.026 = 1.566, so the discharge is Q = 4 × 3 × 1.2^1.566 = 15.97 cfs, or 7,166 gpm, or 10.32 MGD. The submergence ratio is 0.72 / 1.20 = 0.60, which is below 0.7, so the flow is free and the equation applies.

Why it matters

The calculator helps irrigation managers, wastewater operators, hydrologists, environmental technicians and students to turn a level reading into a flow, to choose the throat width for a range of flow and to check the submergence. A Parshall flume has no moving parts and a low head loss, so it is a standard way of measuring the flow of dirty water.

Good to know

Measure the head at the gauge point two thirds of the length of the converging wall from the throat, in a stilling well if the surface is turbulent. Keep the flume level and clean, and check the submergence ratio at the highest flow. Choose a width that gives a head of at least 0.2 ft at the lowest flow, and calibrate the level sensor regularly.

The Manning equation calculator gives the flow of the channel upstream, the critical depth calculator explains the control section of the throat, the weir flow calculator covers another way of measuring the flow and the pipe flow velocity calculator converts the flow to a velocity.

Frequently asked questions

What is a Parshall flume?

A Parshall flume is a measuring structure for open channel flow, made of a converging section, a narrow throat and a diverging section, with a floor that drops in the throat. The flow passes through the critical depth in the throat, so the discharge depends on one measurement only, the upstream head, which makes it easy to meter the flow of irrigation canals, wastewater plants and industrial discharges with a level sensor.

What is the discharge equation?

For a free flow and a throat width W between 1 and 8 ft, the discharge in cfs is Q = 4 W Ha^(1.522 W^0.026), where Ha is the head in feet at the gauge point in the converging section. The equation was found by calibration. For the flumes of 6 in to 9 in and larger than 8 ft, other coefficients apply, which the calculator does not include.

What is submergence?

When the water downstream rises, it can reach the throat and slow the flow, and the flume is submerged. The limit of the free flow is a submergence ratio Hb/Ha of about 0.6 for the small flumes, 0.7 for 1 to 3 ft and 0.8 for 4 to 8 ft. Above this limit, the discharge computed with the free flow equation is too high, and a correction based on the ratio must be applied.

What are the limits of the calculator?

The calculator applies to the standard flume built to the dimensions of the original, with a level approach flow and a head measured at the right place. A deposit in the flume, a poor construction, a high approach velocity or a head measured with a error of a few millimeters change the result. The calibration in the field of a permanent installation is recommended.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.