The sluice gate calculator gives the discharge coefficient, the discharge through a vertical gate in free flow, the depth at the vena contracta, the velocity under the gate and the Froude number downstream, from the width, the opening and the upstream depth.
How the calculation works
- Enter the width of the gate, the opening (the height between the sill and the bottom of the gate) and the upstream water depth.
- The calculator takes a contraction coefficient of 0.611 for the free flow under the gate.
- It finds the discharge coefficient, the discharge, the depth at the vena contracta, the velocity under the gate and the Froude number downstream.
Example
A sluice gate 6 ft wide is opened by 1.5 ft with an upstream depth of 8 ft. The depth at the vena contracta is 0.611 × 1.5 = 0.92 ft. The coefficient is Cd = 0.611 / √(1 + 0.611 × 1.5 / 8) = 0.579. The discharge is 0.579 × 1.5 × 6 × √(2 × 32.2 × 8) = 118.2 cfs. The velocity is 118.2 / (6 × 0.9165) = 21.5 ft/s and the Froude number is 21.5 / √(32.2 × 0.9165) = 3.96.
Why it matters
The calculator helps hydraulic and irrigation engineers, canal operators, dam designers and students to estimate the discharge of a gate for a given opening, to set the opening for a target flow and to check if a hydraulic jump is expected downstream.
Good to know
Check that the flow is free and not submerged, and that the downstream channel can take the supercritical flow. Design a stilling basin where the Froude number is above 1.7, and protect the channel against the erosion. Calibrate the gate with a flow measurement.
Related tools
The weir flow calculator gives the discharge over a weir, the orifice flow calculator gives the flow through an opening, the hydraulic jump calculator finds the conjugate depth downstream and the Froude number calculator classifies the flow.