Sluice gate calculator: discharge of a vertical gate in an open channel

Enter the width of the gate, the gate opening and the upstream depth to get the discharge coefficient, the discharge, the depth at the vena contracta, the velocity under the gate and the Froude number.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

Results

Discharge through the gate

118.2 cfs

Discharge coefficient Cd
0.579
Depth at the vena contracta
0.92 ft
Velocity under the gate
21.5 ft/s
Froude number downstream of the gate
3.96
Supercritical flow below the gate: a hydraulic jump and an energy dissipator are likely

The sluice gate calculator gives the discharge coefficient, the discharge through a vertical gate in free flow, the depth at the vena contracta, the velocity under the gate and the Froude number downstream, from the width, the opening and the upstream depth.

How the calculation works

  • Enter the width of the gate, the opening (the height between the sill and the bottom of the gate) and the upstream water depth.
  • The calculator takes a contraction coefficient of 0.611 for the free flow under the gate.
  • It finds the discharge coefficient, the discharge, the depth at the vena contracta, the velocity under the gate and the Froude number downstream.

Example

A sluice gate 6 ft wide is opened by 1.5 ft with an upstream depth of 8 ft. The depth at the vena contracta is 0.611 × 1.5 = 0.92 ft. The coefficient is Cd = 0.611 / √(1 + 0.611 × 1.5 / 8) = 0.579. The discharge is 0.579 × 1.5 × 6 × √(2 × 32.2 × 8) = 118.2 cfs. The velocity is 118.2 / (6 × 0.9165) = 21.5 ft/s and the Froude number is 21.5 / √(32.2 × 0.9165) = 3.96.

Why it matters

The calculator helps hydraulic and irrigation engineers, canal operators, dam designers and students to estimate the discharge of a gate for a given opening, to set the opening for a target flow and to check if a hydraulic jump is expected downstream.

Good to know

Check that the flow is free and not submerged, and that the downstream channel can take the supercritical flow. Design a stilling basin where the Froude number is above 1.7, and protect the channel against the erosion. Calibrate the gate with a flow measurement.

The weir flow calculator gives the discharge over a weir, the orifice flow calculator gives the flow through an opening, the hydraulic jump calculator finds the conjugate depth downstream and the Froude number calculator classifies the flow.

Frequently asked questions

How does a sluice gate work?

A sluice gate is a vertical plate that slides in guides across a channel. The water goes under the gate and contracts to a jet, whose minimum depth, at the vena contracta, is about 0.61 times the gate opening. The flow downstream is fast and shallow, and it is often followed by a hydraulic jump. The gate controls the flow in irrigation canals, in dams, in water treatment plants and in drainage works.

How is the discharge calculated?

For free flow, the discharge is Q = Cd a b √(2 g y1), where a is the gate opening, b the width, y1 the upstream depth and Cd a coefficient that depends on the ratio a/y1. The calculator uses the energy equation with a contraction coefficient of 0.611, which gives Cd = 0.611 / √(1 + 0.611 a/y1). The value of Cd is about 0.60 for small openings and decreases when the opening increases.

What is the difference between free and submerged flow?

In free flow, the jet leaves the gate with the atmospheric pressure around it, and the downstream depth does not influence the discharge. In submerged flow, the downstream depth covers the jet and the hydraulic jump reaches the gate, which reduces the discharge for the same upstream depth. The calculator is for the free flow, which is the case when the downstream depth is lower than the conjugate depth of the contracted jet.

What are the limits of the calculator?

The calculator uses a constant contraction coefficient and a free flow. It does not include the submerged flow, the gates with a radial shape (tainter gates) which have other coefficients, the approach velocity, the side contractions, the leakage and the gate vibration. The design of a gate and its stilling basin must be made by a hydraulic engineer.

Was this calculator helpful?

Thanks for your feedback!