Skip to content
Omnikalc

Prestress loss calculator for a pretensioned concrete member

Enter the initial stress, the concrete stresses at the strands, the moduli, the volume to surface ratio and the humidity to get the four losses, the total loss and the effective stress.

Updated on
Your inputs
ksi

Value out of range

ksi

Value out of range

ksi

Value out of range

ksi

Value out of range

ksi

Value out of range

ksi

Value out of range

in

Value out of range

%

Value out of range

Results

Total loss

37.0 ksi

Elastic shortening
11.7 ksi
Creep of the concrete
15.9 ksi
Shrinkage of the concrete
5.7 ksi
Relaxation of the strands
3.7 ksi
Total loss as a part of the initial stress
19.6 %
Effective stress after the losses
152.0 ksi

The prestress loss calculator gives the elastic shortening, the creep, the shrinkage, the relaxation, the total loss and the effective stress of the strands of a pretensioned concrete member, from the initial stress, the concrete stresses and the properties of the materials.

How the calculation works

  • Enter the initial stress in the strands and the concrete stresses at their level, after the transfer and from the dead load.
  • Enter the moduli of the concrete and of the strands, the volume to surface ratio and the relative humidity.
  • The calculator finds the four losses, the total loss and the effective stress.

Example

Strands at 189 ksi with a concrete stress of 1.6 ksi at their level have an elastic shortening of 28,500 / 3,900 × 1.6 = 11.7 ksi. The creep is 2 × 28,500 / 4,300 × (1.6 − 0.4) = 15.9 ksi, and the shrinkage with V/S = 3 in and 70 % of humidity is 5.7 ksi. The relaxation is 5 − 0.04 × (5.7 + 15.9 + 11.7) = 3.7 ksi. The total loss is 37.0 ksi, that is 19.6 %, and the effective stress is 152.0 ksi.

Why it matters

The calculator helps precast engineers, bridge designers, students and estimators to see the order of magnitude of the prestress losses, to compare the effect of the humidity, the size of the member and the stress level, and to check the effective stress used in the design of a beam.

Good to know

Use the real concrete stress at the strands found from the prestress, the eccentricity and the self-weight, and check the moduli with the test of the concrete. Compare the result with the lump sum estimate of the project standard. Remember that the losses are higher in a dry climate and in a thin member, and keep the curing humid for the first days.

The prestressed beam stress calculator gives the stresses with the prestress force, the tendon friction loss calculator gives the loss in a post-tensioned tendon, the RC beam flexural capacity calculator gives the moment capacity and the concrete crack width calculator checks the cracks.

Frequently asked questions

What are the prestress losses?

The force in a prestressing strand falls with time from the jacking force to a lower effective force. The losses are the elastic shortening of the concrete at the transfer, the creep and the shrinkage of the concrete, the relaxation of the steel, and, in a post-tensioned member, the friction and the anchor set. A pretensioned member loses usually 15 to 25 % of the initial stress.

How is the elastic shortening found?

When the strands are released, the concrete shortens under the force, and the strands shorten with it and lose stress. The loss is the modular ratio of the strand and the concrete at the transfer times the concrete stress at the level of the strands. The stress is found from the prestress force, the eccentricity and the weight of the member, and the calculator takes it as an input.

How are the creep, the shrinkage and the relaxation found?

The creep is a coefficient times the modular ratio times the net concrete stress, that is the stress after the transfer minus the stress of the superimposed dead loads. The shrinkage depends on the volume to surface ratio and on the humidity. The relaxation of the strands is a function of the stress, and it is reduced by the other losses, because the stress of the strand is lower.

What are the limits of the calculator?

The calculator uses the lump sum formulas of the PCI for a pretensioned member of normal weight concrete, with constants that fit a low-relaxation strand at 70 % of the ultimate stress. It does not cover the post-tensioned members, the lightweight concrete, the time-dependent method, the partial prestressing or the effect of the temperature of the curing. The design must use the method of the standard of the project.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.