A pump works at the intersection of its curve and the system curve of the piping. The pump operating point calculator models both curves from a few known points to find the operating flow and head, the position relative to the rated flow, the friction head and the power absorbed.
How the calculation works
- Enter the shutoff head of the pump (the head at zero flow), its rated flow and the head at the rated flow, from the manufacturer’s curve.
- Enter the static head of the system (the elevation difference plus the pressure to be delivered) and its friction head at the rated flow.
- The calculator models the pump curve as H = H0 − a Q² and the system curve as H = Hs + K Q², and finds their intersection, the operating point: Q = √[(H0 − Hs) / (a + K)].
- It gives the flow, the head, the position relative to the rated flow, the friction head at that flow and the power absorbed by the pump for a given efficiency.
Example
A pump has a shutoff head of 120 ft and gives 90 ft at 400 gpm. The system has a static head of 40 ft and a friction head of 35 ft at 400 gpm. The pump curve coefficient is a = 30 / 400² = 0.0001875 and the system coefficient is K = 35 / 400² = 0.00021875. The operating flow is √[(120 − 40) / (0.0001875 + 0.00021875)] = 443.8 gpm, at a head of 83.08 ft. That is 110.9% of the rated flow. The friction head is 43.08 ft and, at 70% efficiency, the pump absorbs 13.30 hp.
Why it matters
The calculator helps plumbers, mechanical and process engineers, facility managers and students to predict the flow that a pump will give in a piping system, to see the effect of a change in the static head or the friction, and to check if the pump works in a healthy range. It avoids the error of reading the rated flow as the actual flow.
Good to know
Take the points of the pump curve from the manufacturer’s data for the impeller installed. Compute the friction head with the real piping, fittings and valves at the design flow. Check the net positive suction head at the flow found. Leave a margin of 5% to 10% on the head, but do not oversize the pump much, since it then works far to the right of its curve.
Related tools
The pump power calculator gives the shaft power and cost, the NPSH calculator checks the suction, the fan affinity laws calculator shows how speed changes the curve and the valve Cv calculator sizes the control valve that moves the system curve.