Skip to content
Omnikalc

Relative density calculator: how loose or dense a sand is

Enter the maximum, minimum and in-place void ratios of a sand, and the specific gravity of its grains, to get the relative density, the density class and the dry unit weights at the loose, in-place and dense states.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

Value out of range

Results

Relative density Dr = (emax − e) / (emax − emin)

57.5 %

Medium dense
Dry unit weight in place
102.1 pcf
Dry unit weight at the loosest state
89.4 pcf
Dry unit weight at the densest state
114.0 pcf

The relative density of a sand tells how loose or dense it is compared with its extreme states. The relative density calculator computes Dr from the void ratios emax, emin and e, assigns a density class and gives the dry unit weights at the loose, in-place and dense states.

How the calculation works

  • Enter the maximum void ratio emax and the minimum void ratio emin of the sand, measured in the laboratory (ASTM D4254 and D4253), and the void ratio e of the soil in place.
  • Enter the specific gravity of the grains Gs, about 2.65 for a quartz sand, to get the dry unit weights.
  • The calculator computes the relative density Dr = (emax − e) / (emax − emin), which is 0% for the loosest state and 100% for the densest state.
  • It also gives the dry unit weight γd = Gs γw / (1 + e) in place and at the two extreme states, with γw = 62.4 pcf.

Example

A sand has emax = 0.85, emin = 0.45 and an in-place void ratio e = 0.62, with Gs = 2.65. The relative density is (0.85 − 0.62) / (0.85 − 0.45) = 0.23 / 0.40 = 57.5%, a medium dense sand. The dry unit weight in place is 2.65 × 62.4 / 1.62 = 102.1 pcf, between 89.4 pcf at the loosest state and 114.0 pcf at the densest state.

Why it matters

The calculator helps geotechnical engineers, students and site inspectors to judge if a sand fill or a natural sand is dense enough for a foundation, a slab or a pavement, to specify a compaction target as a percentage of Dr, and to screen a site for settlement and liquefaction. It links the void ratio to the strength of the soil.

Good to know

Use emax and emin from tests on the same sand as the field soil, with the same procedure each time. Compute the in-place void ratio from a density test and the water content, not from a guess. A relative density below 35% under a footing is a reason to compact the soil or to change the foundation type.

The porosity and void ratio calculator gives e from the densities, the soil compaction calculator targets a density in a fill, the bearing capacity calculator uses the strength of the sand and the soil permeability test calculator measures the flow through it.

Frequently asked questions

What is the relative density of a soil?

The relative density Dr tells where a granular soil stands between its loosest and its densest possible states. A value of 0% means that the soil is as loose as it can be and 100% means that it is as dense as it can be. It is more useful than the void ratio alone, since two sands with the same void ratio can have very different ranges of possible densities.

How are emax and emin measured?

The maximum void ratio is measured by pouring dry sand gently into a mold, which gives the loosest state, in ASTM D4254. The minimum void ratio is measured by vibrating the sand in the mold under a surcharge, which gives the densest state, in ASTM D4253. Both tests apply to clean sands and gravels with less than about 15% fines.

What are the density classes?

The usual classes are very loose (below 15%), loose (15% to 35%), medium dense (35% to 65%), dense (65% to 85%) and very dense (above 85%). They are related to the friction angle and to the field tests: the SPT blow count rises with Dr and with the depth. A loose saturated sand is the main candidate for liquefaction in an earthquake.

What are the limits of the calculation?

The formula assumes that the lab extremes are the true extremes of the field soil, which is only approximately true. The scatter of the lab tests, the sampling disturbance and the fines content can change Dr by 10 points or more. For design, use it with the blow counts of the SPT or the cone resistance, not alone.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.