Sand cone field density and compaction calculator

Enter the weights of the jar and sand, the sand density, the weight and moisture of the soil and the Proctor maximum to get the dry density and the relative compaction.

Updated on
Your inputs
lb

Value out of range

lb

Value out of range

lb

Value out of range

lb/ft³

Value out of range

lb

Value out of range

%

Value out of range

lb/ft³

Value out of range

%

Value out of range

Results

Relative compaction

96.6 %

Weight of sand in the hole
5.35 lb
Volume of the hole
0.0563 ft³
Wet unit weight of the soil
124.3 lb/ft³
Dry unit weight of the soil
112.5 lb/ft³
Margin over the required compaction
1.6 %
The compaction meets the specification

The sand cone calculator gives the volume of the test hole, the wet and dry unit weight of a compacted soil and its relative compaction against the Proctor maximum, with the margin over the specification.

How the calculation works

  • Enter the weights of the jar and sand before and after the test, and the weight of the sand in the cone.
  • Enter the calibrated unit weight of the sand, the weight of the wet soil taken from the hole and its moisture content.
  • Enter the maximum dry unit weight of the Proctor test and the compaction required. The calculator gives the dry unit weight and the relative compaction.

Example

The jar weighs 14.5 lb before the test and 6.1 lb after. The cone and plate take 3.05 lb of sand, so the sand in the hole weighs 14.5 − 6.1 − 3.05 = 5.35 lb. With a calibrated sand of 95 lb/ft³, the volume of the hole is 5.35 / 95 = 0.0563 ft³. The wet soil weighs 7 lb, so the wet unit weight is 124.3 lb/ft³. At a moisture content of 10.5 percent, the dry unit weight is 124.3 / 1.105 = 112.5 lb/ft³. The Proctor maximum is 116.5 lb/ft³, so the relative compaction is 96.6 percent, which is 1.6 points above the 95 percent required.

Why it matters

The calculator helps inspectors, technicians and contractors to reduce the field density test on site and to know at once whether the lift passes or must be re-compacted. It avoids errors in the chain of the weights and of the volumes.

Good to know

Calibrate the density of the sand and the weight of the sand in the cone with the equipment of the job, and again when the sand is changed. Do not walk or run an engine near the test during the pouring. Dig the hole with straight walls, save all the soil and seal it in a container to measure the moisture. Use the Proctor curve of the same soil: if the soil changes, the maximum changes, and the relative compaction is no longer valid.

The soil compaction calculator gives the volume of soil to compact, the compaction roller production calculator sizes the equipment, the dynamic compaction calculator gives the depth of influence of heavy tamping and the soil gradation calculator classifies the soil that you test.

Frequently asked questions

What is the sand cone test?

The sand cone test (ASTM D1556) measures the in-place density of a compacted soil. A small hole is dug in the fill, and all the soil is saved and weighed. The volume of the hole is found by filling it with a clean dry sand of known density that is poured from a jar through a cone. The wet density is the weight of the soil divided by the volume, and the dry density follows from the moisture content.

Why is the weight of the sand in the cone subtracted?

The sand that fills the cone and the base plate does not go in the hole. The weight of this sand is found before the field work by running the test on a flat surface. The sand in the hole is the loss of weight of the jar minus the sand in the cone. An error in this value changes the volume, so it must be calibrated with the same jar, cone and sand.

What is the relative compaction?

The relative compaction is the ratio of the dry density measured in the field to the maximum dry density of the Proctor test (ASTM D698 or D1557) on the same soil, in percent. A common specification is 95 percent of the standard or modified Proctor. The compaction is often checked with the moisture, which should be near the optimum, within about two points.

What are the sources of error?

The main sources are the vibration of the sand during the test, which makes it denser, a hole with a rough wall, the loss of some soil, an error in the moisture and the use of a Proctor maximum from a different soil. In soils with coarse particles, correct the maximum density for the oversize. Run a check with a nuclear gauge when many tests are needed.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.