Skip to content
Omnikalc

Scaffold tie calculator: wind force on the ties of a building scaffold

Enter the scaffold size, the wind speed, the force coefficient, the tie spacing and the tie capacity to get the wind pressure, the total force, the number of ties, the force on each tie and the ratio.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

mph

Value out of range

ft

Value out of range

ft

Value out of range

lb

Value out of range

Results

Force on each tie

1,536 lb

Wind pressure
6.4 psf
Total wind force on the scaffold
9,216 lb
Number of ties
6
Ratio to the tie capacity
0.61
The ties have enough capacity

The scaffold tie calculator gives the wind pressure, the total wind force, the number of ties, the force on each tie and the ratio to the tie capacity of a tied scaffold, from the height, the length, the wind speed, the force coefficient and the spacing of the ties.

How the calculation works

  • Enter the height and the length of the scaffold and the wind speed to check.
  • Choose the force coefficient that fits the face of the scaffold, and enter the vertical and horizontal spacing of the ties.
  • Enter the capacity of one tie to get the wind pressure, the total force, the number of ties, the force on each tie and the ratio.

Example

A scaffold of 40 ft by 60 ft is checked for a wind of 50 mph, so the pressure is 0.00256 × 50² = 6.4 psf. For a bare scaffold with a coefficient of 0.6, the total force is 6.4 × 0.6 × 40 × 60 = 9,216 lb. Ties at 20 ft vertically and 20 ft horizontally give 2 × 3 = 6 ties, so each tie carries 9,216 / 6 = 1,536 lb. For a tie capacity of 2,500 lb, the ratio is 0.61.

Why it matters

The calculator helps scaffold designers, erectors, safety managers, façade contractors and students to check the ties of a scaffold before a storm, to see the effect of the netting or the sheeting and to choose the spacing and the capacity of the ties.

Good to know

Install the ties as the scaffold goes up, and never remove a tie before the scaffold is dismantled to that level. Check the anchors in the real wall with a pull test, and use more ties or remove the sheeting when a strong wind is forecast. Stop the work on the scaffold when the wind is over the limit of the manufacturer, and inspect the ties after every storm.

The scaffold calculator estimates the materials of a scaffold, the wind load calculator gives the wind pressure on a structure, the wind cladding pressure calculator gives the pressure on the walls and the hurricane tie-down uplift force calculator checks the roof anchors.

Frequently asked questions

Why are scaffolds tied to the building?

A tall scaffold is a slender structure, and the wind can overturn it or pull it from the wall. The ties connect the scaffold to the building and carry the horizontal forces of the wind, in tension and in compression, back to the structure. Rules and standards give the maximum height of a free-standing scaffold and the spacing of the ties for a tied scaffold.

How is the wind force calculated?

The velocity pressure is 0.00256 × V² in psf, with V in mph (0.613 × V² in Pa, with V in m/s). The force is the pressure times the force coefficient and the area of the face. A bare scaffold lets the wind pass through and has a low coefficient, but a scaffold with netting or sheeting acts like a wall, and the force can be 2 to 3 times higher.

What spacing of the ties is used?

Common rules ask for a tie at every 20 ft (6 m) horizontally and at every 26 ft (8 m) or less vertically for a bare scaffold, with the first tie at the height of 4 times the base width. For a sheeted scaffold, the spacing is smaller. The ties are placed at the lifts with a standard, and a few of them must resist the forces away from the building and toward it.

What are the limits of the calculator?

The calculator gives an average force on each tie. It does not include the corners and the edges where the pressure is higher, the dynamic effect of the gusts, the load on the scaffold that adds the overturning moment, the capacity of the anchor in the wall or the loads from the materials and the people. A competent person or an engineer must design a high scaffold, and the anchors must be tested in the real wall.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.