Skip to content
Omnikalc

Single effect evaporator calculator: steam use and heating area to concentrate a solution

Enter the feed flow and concentrations, the temperatures and the heat transfer coefficient to get the water evaporated, the steam consumption, the steam economy and the heating surface area of a single-effect evaporator.

Updated on
Your inputs
lb/h

Value out of range

%

Value out of range

%

Value out of range

°F

Value out of range

°F

Value out of range

°F

Value out of range

Btu/lb

Value out of range

Btu/lb

Value out of range

Btu/lb·°F

Value out of range

Btu/h·ft²·°F

Value out of range

Results

Heating surface area

275.1 ft²

Water evaporated
7,500 lb/h
Heating steam consumption
8,725 lb/h
Steam economy (kg of vapor per kg of steam)
0.860
Typical economy of a single effect
Heat duty
8,253,500 Btu/h

A single-effect evaporator concentrates a solution by boiling off water with heating steam. The single effect evaporator calculator gives the water evaporated, the steam consumption, the steam economy, the heat duty and the heating surface area from the feed, the concentrations and the temperatures.

How the calculation works

  • Enter the feed flow rate, the solids content of the feed and the solids content wanted in the product.
  • Enter the feed temperature, the boiling temperature in the evaporator (lower under vacuum) and the temperature of the heating steam, with the latent heats and the specific heat of the feed.
  • The calculator finds the water evaporated by a solids balance, V = F × (1 − xF / xP), and the heat duty needed to heat the feed and to evaporate the water.
  • It gives the steam consumption, the steam economy and the heating surface area A = Q / [U × (Ts − Tb)].

Example

A single-effect evaporator concentrates 10,000 lb/h of a solution from 5% to 20% solids. The water evaporated is 10,000 × (1 − 5 / 20) = 7,500 lb/h. The feed at 77 °F boils at 150 °F (latent heat 1,008 Btu/lb), so the heat duty is 7,500 × 1,008 + 10,000 × 0.95 × 73 = 8,253,500 Btu/h. With steam at 250 °F (946 Btu/lb) the steam consumption is 8,725 lb/h and the economy is 0.860. With U = 300, the surface is 8,253,500 / (300 × 100) = 275.1 ft².

Why it matters

The calculator helps process engineers in food, dairy, chemical and wastewater plants, as well as students, to make a first design or a check of an evaporator, to estimate the steam bill and to compare the benefit of a lower boiling temperature or a preheated feed. It is the starting point before a multiple-effect study.

Good to know

Take the latent heats and the steam temperature from steam tables at the real pressures. Subtract the boiling point elevation from the available temperature difference for salt, sugar or caustic solutions. Use a lower value of U for viscous products. Add a margin of 10 to 20% to the area for fouling.

The boiling point elevation calculator gives the rise caused by dissolved solids, the heat exchanger LMTD calculator covers the temperature difference, the overall heat transfer coefficient calculator gives U and the latent heat calculator gives the energy of a phase change.

Frequently asked questions

How much water must be evaporated?

The solids are not evaporated, so the mass of solids is the same in the feed and in the product. A balance gives the product flow F × xF / xP and the water evaporated V = F × (1 − xF / xP). Concentrating from 5% to 20% solids removes three quarters of the feed as water, while concentrating from 20% to 40% removes only half of the remaining feed.

What is the steam economy?

The steam economy is the mass of water evaporated per mass of heating steam used. In a single-effect evaporator it is a little under 1, because each kilogram of steam that condenses can boil about one kilogram of water. Using the vapor made in a first effect to heat a second effect, in a multiple-effect plant, gives an economy close to the number of effects, which is why large evaporators use three to six effects.

Why does the feed temperature matter?

A cold feed must be heated to the boiling point before it can evaporate, and this uses steam. A feed already at the boiling temperature needs only the latent heat of evaporation, and the economy is highest. A feed above the boiling point flashes when it enters and adds to the evaporation. Preheating the feed with the condensate or the vapor improves the economy.

What is not included in this calculator?

The boiling point elevation caused by the dissolved solids, which reduces the temperature difference available for heat transfer, is not included, and neither are the heat losses to the room, the change of the specific heat and the viscosity effect on U as the product concentrates. For salt, sugar or caustic solutions, subtract the boiling point rise from the temperature difference to get a realistic area.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.