Enter the steam flow, the pressure, the pipe diameter and a target velocity to get the specific volume, the volume flow, the steam velocity in the pipe and the inside diameter required.

Updated on
Your inputs
lb/h

Value out of range

in

Value out of range

Results

Steam velocity in the pipe

6,298 ft/min

Velocity within the normal range for steam
Specific volume of the steam
3.88 ft³/lb
Volume flow rate of the steam
323.3 ft³/min
Inside diameter required for the target velocity
2.72 in
Pipe diameter over required diameter
113 %

The steam pipe sizing calculator gives the velocity of saturated steam in a pipe of known diameter and the inside diameter required for a target velocity, from the steam flow rate and the pressure.

How the calculation works

  • Enter the steam flow rate and choose the steam pressure, from which the calculator takes the specific volume of saturated steam.
  • Enter the inside diameter of the pipe that you are checking (3.068 in for 3 in Schedule 40 pipe).
  • Choose a target velocity: 6,000 to 8,000 ft/min is common for steam mains, with up to 10,000 ft/min on long, high-pressure lines.
  • The calculator gives the velocity in your pipe and the inside diameter required for the target velocity, so that you can choose the nominal pipe size.

Example

A line carries 5,000 lb/h of saturated steam at 100 psig, where the specific volume is 3.88 ft³/lb. The volume flow is 5,000 × 3.88 / 60 / 60 = 5.39 ft³/s, or 323.3 ft³/min. In a 3.068 in pipe (area 0.0513 ft²), the velocity is 6,298 ft/min. For a target of 8,000 ft/min, the required inside diameter is 2.72 in, so the 3 in pipe is 113% of the required size and could be reduced to 2.5 in.

Why it matters

The calculator helps boiler room and plant engineers, mechanical contractors, energy managers and students to size a steam main or a branch, to check an existing line for noise or erosion and to avoid an oversized pipe. It is a first check before the pressure drop and heat loss calculations.

Good to know

Round the required diameter up to the next nominal pipe size. Check the pressure drop on long lines. Use a lower velocity for wet steam or near turbines. Provide drip legs and traps at low points and ahead of control valves, and support the pipe so that it keeps its slope.

The pipe flow velocity calculator covers any fluid, the flash steam calculator gives the steam released by hot condensate, the steam trap sizing calculator sizes the drains and the boiler size calculator covers a house boiler.

Frequently asked questions

What velocity is recommended for steam pipes?

Common design velocities for saturated steam are 4,000 to 8,000 ft/min (20 to 40 m/s) for distribution mains, and up to 10,000 ft/min for long, high-pressure lines. Lower velocities of 3,000 to 5,000 ft/min are used for branch lines and where noise matters. A velocity above 12,000 ft/min causes noise, erosion of the fittings, wet steam damage and a high pressure drop.

Why does the pressure change the diameter?

Steam at a higher pressure is denser, so a given mass flow takes up less volume. At 15 psig, 1 lb of steam occupies 13.7 ft³, and at 150 psig only 2.75 ft³. For the same velocity, a high-pressure line is therefore much smaller than a low-pressure line, which is why steam is usually distributed at high pressure and reduced near the users.

Is the velocity the only criterion?

No. A long line must also be checked for the pressure drop, which should stay under 1 psi per 100 ft or so, and for the heat loss and condensation, which depend on the insulation. Drainage points with steam traps are needed every 100 to 150 ft and at the low points. The pipe must slope in the flow direction by about 1 in per 40 ft to move the condensate to the drains.

What about superheated steam?

The specific volume of superheated steam is larger than that of saturated steam at the same pressure, so the velocity for a given flow is higher. This calculator uses saturated steam values from the steam tables. For superheated steam, correct the specific volume with the steam tables, or use about 1% more volume for each 5 °F of superheat as a rough estimate.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.