Skip to content
Omnikalc

Steel tension member calculator: design strength of a bolted plate in tension (AISC 360)

Enter the plate size, the bolts, the pitch, the end distance, the gauge, the steel grade and the load to get the yielding, rupture and block shear strengths, the design strength and the ratio of the load to it.

Updated on
Your inputs
in

Value out of range

in

Value out of range

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

kips

Value out of range

Results

Design tension strength

152.3 kips

Yielding of the gross section
180.0 kips
Rupture of the net section
152.3 kips
Block shear rupture
231.6 kips
Load over strength
0.79
The member has enough strength

The steel tension member calculator gives the design strength of a bolted plate in tension by the three limit states of AISC 360: yielding of the gross section, rupture of the net section and block shear, and compares it with the factored load.

How the calculation works

  • Enter the thickness and the width of the plate, the diameter of the bolts, the number of bolts in each of the two lines, the pitch, the end distance and the gauge.
  • Choose the steel grade and the shear lag factor U, which is 1.0 for a plate connected over its whole width.
  • Enter the factored tension load.
  • The calculator finds the strength by yielding of the gross section, rupture of the net section and block shear, the lowest one as the design strength, and the ratio of the load to it.

Example

A plate of 8 in by 0.5 in of A572 Grade 50 steel has two lines of three 3/4 in bolts (holes of 0.875 in) at a 3 in pitch, 1.5 in of end distance and 4 in of gauge. Yielding gives 0.9 × 50 × 4.0 = 180.0 kips. Rupture on the net area of (8 − 2 × 0.875) × 0.5 = 3.125 in² gives 0.75 × 65 × 3.125 = 152.3 kips. Block shear gives 231.6 kips. The design strength is 152.3 kips by rupture, and a load of 120 kips is 0.79 of it.

Why it matters

The calculator helps structural engineers, steel detailers, fabricators and students to check a tension plate, a hanger or a brace connection, to see which limit state governs and to try a different bolt pattern or grade. It reproduces the standard hand calculation of chapters D and J of AISC 360.

Good to know

Check also the bolts in shear and bearing, the tear-out at the end holes and the strength of the connected part. Use a shear lag factor that corresponds to the real connection, and increase the end distance and the pitch if the block shear governs. Take the load from the combinations of the code, and have the design checked by a qualified engineer.

The bolt shear capacity calculator checks the bolts, the Whitmore gusset width calculator checks a gusset plate, the fillet weld strength calculator covers welded connections and the beam bearing length calculator covers the bearing of a beam.

Frequently asked questions

What are the limit states of a tension member?

A tension member can fail in three ways at the connection. The gross section can yield over its length, which gives large elongations. The net section through the bolt holes can rupture, since it has less area. And a block of material can tear out along the bolts, with shear on the sides and tension on the end, which is the block shear. AISC 360 requires the lowest of the three design strengths.

How is the net area found?

The net area is the gross area minus the area of the holes in the section considered. For the calculation, the width of a hole is taken as the nominal diameter of the bolt plus 1/16 in for the clearance and another 1/16 in for the damage of the punching, so 0.875 in for a 3/4 in bolt. The effective net area is the net area multiplied by the shear lag factor U, which is less than 1.0 when not all the elements are connected.

What is block shear?

Block shear is the tearing of a block of material at the end of a connection: the shear fails on the planes along the lines of bolts and the tension fails on the plane between them. The strength is 0.6 Fu Anv + Ubs Fu Ant, limited by 0.6 Fy Agv + Ubs Fu Ant, multiplied by φ = 0.75. A larger end distance and a larger pitch increase it, which is why the end distance of the bolts must not be too small.

What are the limits of the calculator?

The calculator treats a plate with two symmetrical lines of bolts and a uniform tension. It does not check the bolts themselves, the bearing and tear-out of the holes, the slenderness, the fatigue, the eccentricity of an angle, or the connection plates. The strengths are the LRFD design strengths of AISC 360. A qualified structural engineer must check the member and its connection.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.