The timber connection calculator solves the six yield limit equations of the NDS (the Johansen model) for a bolt or dowel in single shear and gives the governing mode and the lateral design value of one fastener.
How the calculation works
- Enter the diameter of the bolt or dowel, the thickness of the main and side members and their dowel bearing strengths.
- Enter the bending yield strength of the fastener, the load duration factor, the number of fasteners and the design load.
- The calculator solves the six yield limit equations, gives the governing mode, the lateral design value of one fastener and the ratio of the load to the capacity.
Example
A 1/2 in bolt joins a 1.5 in side member to a 3.5 in main member, both with a dowel bearing strength of 5,600 psi, and the bolt has a bending yield strength of 45,000 psi. The ratios are Re = 1 and Rt = 2.33. The six modes give 2,450, 1,050, 913, 1,103, 615, 716 lb, so mode IIIs governs with 615 lb per fastener. Four bolts at a load duration factor of 1.0 carry 2,459 lb, and a load of 2,000 lb gives a ratio of 0.81.
Why it matters
The calculator helps timber designers, engineers, builders and students to check a bolted connection of a deck, a beam to a post or a truss heel, and to see how the thickness of the members, the diameter and the bearing strength change the capacity and the type of failure.
Good to know
Check that the thickness of the side member is large enough for the diameter. A side member thinner than about four diameters usually fails by crushing, which is the brittle mode. Use the bending yield strength of the fastener, 45,000 psi for a common bolt, and the bearing strength for the lower of the species. The result is the reference value, and the adjustment factors for the duration of the load, the wet service, the temperature, the group action and the geometry multiply it, so apply each one that the code requires before you compare it to the load.
Related tools
The bolt shear capacity calculator checks a steel bolt, the lag screw calculator gives the withdrawal of a lag screw, the shear flow calculator spaces fasteners in a built-up beam and the wood beam span calculator checks the beam that the connection supports.