Skip to content
Omnikalc

Timber connection lateral capacity calculator (yield limit equations)

Enter the fastener diameter, the member thicknesses, the bearing strengths and the load to get the six yield modes, the governing mode and the lateral design value of a bolt or dowel.

Updated on
Your inputs
in

Value out of range

in

Value out of range

in

Value out of range

psi

Value out of range

psi

Value out of range

psi

Value out of range

Value out of range

lb

Value out of range

Results

Reference lateral design value per fastener

615 lb

Governing yield mode (1 = Im, 2 = Is, 3 = II, 4 = IIIm, 5 = IIIs, 6 = IV)
5
A ductile mode with fastener bending governs
Adjusted capacity of the connection
2,459 lb
Demand to capacity ratio
0.81
The connection carries the load

The timber connection calculator solves the six yield limit equations of the NDS (the Johansen model) for a bolt or dowel in single shear and gives the governing mode and the lateral design value of one fastener.

How the calculation works

  • Enter the diameter of the bolt or dowel, the thickness of the main and side members and their dowel bearing strengths.
  • Enter the bending yield strength of the fastener, the load duration factor, the number of fasteners and the design load.
  • The calculator solves the six yield limit equations, gives the governing mode, the lateral design value of one fastener and the ratio of the load to the capacity.

Example

A 1/2 in bolt joins a 1.5 in side member to a 3.5 in main member, both with a dowel bearing strength of 5,600 psi, and the bolt has a bending yield strength of 45,000 psi. The ratios are Re = 1 and Rt = 2.33. The six modes give 2,450, 1,050, 913, 1,103, 615, 716 lb, so mode IIIs governs with 615 lb per fastener. Four bolts at a load duration factor of 1.0 carry 2,459 lb, and a load of 2,000 lb gives a ratio of 0.81.

Why it matters

The calculator helps timber designers, engineers, builders and students to check a bolted connection of a deck, a beam to a post or a truss heel, and to see how the thickness of the members, the diameter and the bearing strength change the capacity and the type of failure.

Good to know

Check that the thickness of the side member is large enough for the diameter. A side member thinner than about four diameters usually fails by crushing, which is the brittle mode. Use the bending yield strength of the fastener, 45,000 psi for a common bolt, and the bearing strength for the lower of the species. The result is the reference value, and the adjustment factors for the duration of the load, the wet service, the temperature, the group action and the geometry multiply it, so apply each one that the code requires before you compare it to the load.

The bolt shear capacity calculator checks a steel bolt, the lag screw calculator gives the withdrawal of a lag screw, the shear flow calculator spaces fasteners in a built-up beam and the wood beam span calculator checks the beam that the connection supports.

Frequently asked questions

What are the yield limit equations?

They are the equations of the NDS for wood construction, based on the European yield theory of Johansen. They give the lateral load that a bolt, a dowel, a lag screw or a nail can carry in one shear plane for each possible failure mode: crushing of the wood in the main member (Im), in the side member (Is), rotation of the fastener (II) and one or two plastic hinges in the fastener (IIIm, IIIs, IV). The smallest value governs.

Which mode is better?

The modes with a plastic hinge in the fastener, IIIm, IIIs and IV, are ductile. The connection bends and slips before it fails, so it warns before it collapses. Modes Im and Is are crushing of the wood and are more brittle, and they happen with thin members, a stiff fastener or soft wood. Thicker members, a smaller diameter or more fasteners move the connection towards the ductile modes.

What do I put for the dowel bearing strength?

Use the value of the NDS for the specific gravity of the wood and the diameter of the fastener, for example 5,600 psi for a 1/2 in bolt in Douglas fir-larch loaded parallel to the grain. For a load across the grain the strength is much lower and the angle factor changes the result. The calculator is for a load parallel to the grain.

What does the calculator leave out?

The calculator leaves out the group action factor for several fasteners in a row, the geometry factors for end distance, edge distance and spacing, the wet service and temperature factors, a load across the grain, double shear and steel side plates. Apply them to the value given here and check the minimum spacings of the code.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.